1.
To configure the snapshot space settings of QReplica, click the
“configuration”
button.
There are three settings in the
QReplica configuration
menu,
The
Snapshot space
specifies the ratio of snapshot space allocated to the source VD
automatically when the snapshot space is not configured in advance. The default ratio is
2 to 1. It means when the replication job is creating, the subsystem will automatically
use the free space of RG to create a snapshot space which size is double of the source
VD.
The
Threshold
setting will monitor the utilization of snapshot space. When the used
snapshot space achieves the threshold, the subsystem will automatically take a new
snapshot and start the replication job. The purpose of threshold is to prevent the
incremental copy fail immediately when running out of snapshot space. For example, the
default threshold is 50%, and the system will check the snapshot space every hour.
When the snapshot space is used over 50%, the subsystem will automatically replicate
data from the source VD to the target VD. Next time, when the rest snapshot space has
been used over 50%, in other words, the total snapshot space has been used over 75%,
the subsystem will start the replication job again.
The
Restart the task an hour later if failed
setting is used when running out of
snapshot space, the replication job will stop because there is no more available snapshot
space. If this option has been check, the subsystem will automatically clear the
snapshots to release snapshot space, and the replication job will restart the task after an
hour.
IMPORTANT! These two settings,
Threshold
and
Restart the task
an hour later if failed
, will take effect only when the replication job
is configured to run by schedule.
Summary of Contents for EP-3164D-GAS3
Page 1: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual Revision 1 1 ...
Page 85: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 85 ...
Page 89: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 89 ...
Page 114: ...iSCSI GbE to SAS SATA II RAID Subsystem 114 User Manual ...
Page 149: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 149 8 Install 9 Installation succeeded ...
Page 159: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 159 34 Done ...