iSCSI GbE to SAS/SATA II RAID Subsystem
86
User Manual
If
“Auto shutdown”
has been checked, the system will shutdown automatically when
voltage or temperature is out of the normal range. For better data protection, please
check
“Auto Shutdown”
.
For better protection and avoiding single short period of high temperature triggering
auto shutdown, the RAID controller evaluates multiple conditions for triggering auto
shutdown. Below are the details of when the Auto shutdown will be triggered.
1.
There are several sensors placed on systems for temperature checking.
System will check each sensor for every 30 seconds. When one of these
sensor is over high temperature threshold for continuous 3 minutes, auto
shutdown will be triggered immediately.
2.
The core processor temperature limit is 80
℃
. The iSCSI NIC temperature limit
is 65
℃
. The SAS expandor and SAS controller temperature limit is 65
℃
.
3.
If the high temperature situation doesn’t last for 3 minutes, system will not
trigger auto shutdown.
5.5.2 UPS
“UPS”
is used to set up UPS (
U
ninterruptible
P
ower
S
upply).
Currently, the system only supports and communicates with APC (American Power
Conversion Corp.) smart UPS. Please review the details from the website:
http://www.apc.com/
.
First, connect the system and APC UPS via RS-232 for communication. Then set up the
shutdown values (shutdown battery level %) when power is failed. UPS in other
companies can work well, but they have no such communication feature with the
system.
Summary of Contents for EP-3164D-GAS3
Page 1: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual Revision 1 1 ...
Page 85: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 85 ...
Page 89: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 89 ...
Page 114: ...iSCSI GbE to SAS SATA II RAID Subsystem 114 User Manual ...
Page 149: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 149 8 Install 9 Installation succeeded ...
Page 159: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 159 34 Done ...