iSCSI GbE to SAS/SATA II RAID Subsystem
User Manual
47
Chapter 5 Configuration
5.1 Web GUI Management Interface Hierarchy
The below table is the hierarchy of the management GUI.
System configuration
System
setting
Æ
System name / Date and time / System indication
Network
settin
g
Æ
MAC address / Address / DNS / Port
Login
setting
Æ
Login configuration / Admin password / User password
setting
Æ
Notification
setting
Æ
SNMP / Messenger / System log server / Event log filter
iSCSI configuration
NIC
Æ
Show information for:(Controller 1/ Controller 2)
Aggregation / IP settings for iSCSI ports / Become
default gateway / Enable jumbo frame / Ping host
Entity
property
Æ
Entity name / iSNS IP
Node
Æ
Show information for:(Controller 1/ Controller 2)
Authenticate / Change portal / Rename alias/ User
Session
Æ
Show information for:(Controller 1/ Controller 2)
List connection / Delete
CHAP
account
Æ
Create / Modify user information / Delete
Volume configuration
Physical
disk
Æ
Set Free disk / Set Global spare / Set Dedicated spare /
Upgrade / Disk Scrub / Turn on/off the indication LED /
More information
RAID
group
Æ
Create / Migrate / Activate / Deactivate / Parity check /
Delete / Set preferred owner /Set disk property / More
information
Virtual
disk
Æ
Create / Extend / Parity check / Delete / Set property /
Attach LUN / Detach LUN / List LUN / Set clone / Clear
clone / Start clone / Stop clone / Schedule clone / Set
snapshot space / Cleanup snapshot / Take snapshot /
Auto snapshot / List snapshot / More information
Snapshot
Æ
Set snapshot space / Auto snapshot / Take snapshot /
Export / Rollback / Delete/ Cleanup snapshot
Logical
unit
Æ
Attach / Detach/ Session
Enclosure management
Hardware
monitor
Æ
Controller 1 / BPL / Controller 2 / Auto shutdown
UPS
Æ
UPS Type / Shutdown battery level / Shutdown delay /
Shutdown UPS
SES
Æ
Enable / Disable
S.M.A.R.T.
Æ
S.M.A.R.T. information
(Only for SATA hard drives)
Maintenance
System
information
Æ
System information
Event
log
Æ
Download / Mute / Clear
Upgrade
Æ
Browse the firmware to upgrade
Summary of Contents for EP-3164D-GAS3
Page 1: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual Revision 1 1 ...
Page 85: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 85 ...
Page 89: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 89 ...
Page 114: ...iSCSI GbE to SAS SATA II RAID Subsystem 114 User Manual ...
Page 149: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 149 8 Install 9 Installation succeeded ...
Page 159: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 159 34 Done ...