iSCSI GbE to SAS/SATA II RAID Subsystem
User Manual
99
To migrate the RAID level, please follow below procedures.
1.
Select
“/ Volume configuration / RAID group”
.
2.
Check the gray button next to the RG number; click
“Migrate”
.
3.
Change the RAID level by clicking the down arrow to
“RAID 5”
. There will be a
pup-up which indicates that HDD is not enough to support the new setting of RAID
level, click
“Select PD”
to increase hard drives, then click
“OK“
to go back to setup
page. When doing migration to lower RAID level, such as the original RAID level is
RAID 6 and user wants to migrate to RAID 0, system will evaluate whether this
operation is safe or not, and appear a warning message of
"Sure to migrate to a
lower protection array?”
.
4.
Double check the setting of RAID level and RAID PD slot. If there is no problem,
click
“OK“
.
5.
Finally a confirmation page shows the detail of RAID information. If there is no
problem, click
“OK”
to start migration. System also pops up a message of
“Warning: power lost during migration may cause damage of data!”
to give
user warning. When the power is abnormally off during the migration, the data is in
high risk.
6.
Migration starts and it can be seen from the
“status”
of a RG with
“Migrating”
. In
“/ Volume configuration / Virtual disk”
, it displays a
“Migrating”
in
“Status”
and complete percentage of migration in
“R%”
.
A RAID 0 with 3 physical disks migrates to RAID 5 with 4 physical disks.
Summary of Contents for EP-3164D-GAS3
Page 1: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual Revision 1 1 ...
Page 85: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 85 ...
Page 89: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 89 ...
Page 114: ...iSCSI GbE to SAS SATA II RAID Subsystem 114 User Manual ...
Page 149: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 149 8 Install 9 Installation succeeded ...
Page 159: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 159 34 Done ...