SECTION 5
Pronar N262 N262/1
5.37
FIG. 5.14
Replacing spreading disc blades
(1) blade, (2) M16x40 bolt, (3) M12 self locking nut, (4) M12x30 bolt, (5) Z16,3 spring washer
In order to replace a spreading disc blade (1):
unscrew nut (3),
take out bolt (4) ,
unscrew bolt (2) and remove washer (5),
replace blades (1) with new ones, check condition of bolts and nuts, if
necessary replace,
install in reverse order.
All blades are replaced in the same way. When installing a blade, pay attention to rotation
direction of spreading disc and mounting in proper holes.
Summary of Contents for PRONAR N262