5.44
TABLE 5.6
Tightening torque for nut and bolt connections
5.8
(1)
8.8
(1)
10.9
(1)
THREAD
METRIC
MD [Nm]
M10
37
49
72
M12
64
85
125
M14
100
135
200
M16
160
210
310
M20
300
425
610
M24
530
730
1,050
M27
820
1,150
1,650
M30
1,050
1,450
2,100
(1)
– resistance class according to DIN ISO 898 standard, (M
D
) – tightening torque, (d) thread diameter
Hydraulic conduits should be tightened using torque of 50 – 70 Nm.