![PRONAR NV161/1 Operator'S Manual Download Page 111](http://html.mh-extra.com/html/pronar/nv161-1/nv161-1_operators-manual_1617395111.webp)
SECTION 5
Pronar NV161/1
│
NV161/2
│
NV161/3
│
NV161/4
│
NV161/5
5.27
the respiratory tract. A hazard only occurs when oil is strongly atomised (oil vapour), or in the
case of fire during which toxic compounds may be released. Oil fires should be quenched
with the use of carbon dioxide, foam or extinguisher steam.
5.5
MAINTENANCE OF MANURE SPREADER GEARS
Maintenance of the adapter drive gear and the floor conveyor drive gear involves checking
gear oil level in the inspection opening, topping up with gear oil and gear oil change.
Check oil level in the gears in the transparent inspection opening before each start of the
machine. Turn off the gears and wait until oil cools down before changing oil.
Oil in both gears should be changed after the first 50 working hours and then every 600
working hours.
Oil change should be conducted at working temperature, when the machine has worked for
several minutes. Then, possible contamination in the gear is mixed with the oil and is drained
out with it.
WARNING
There are two different options of the adapter drive gear offered by the manufacturer:
“option 1” – with the drain plug located in the central gear.
“option 2” – with the drain plugs located in the central and side gears.
POSITION OF GEAR
TYPE OF GREASE
QUANTITY
A
Adapter gear mechanism – “option 1”
7l
A
Adapter gear mechanism – “option 2”
10l
B
Feeding mechanism (NV161/1, NV161/2,
NV161/3)
3.8l
B
Feeding mechanism (NV161/4 NV161/5)
SAE 90 EP (API GL-
5 SAE 80W/90)
6.6l
Summary of Contents for NV161/1
Page 2: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 13: ...SECTION 1 BASIC INFORMATION ...
Page 27: ...SECTION 2 SAFETY ADVICE ...
Page 45: ...SECTION 3 DESIGN AND OPERATION ...
Page 67: ...SECTION 4 CORRECT USE ...
Page 84: ...Pronar NV161 1 NV161 2 NV161 3 NV161 4 NV161 5 SECTION 4 4 18 ...
Page 85: ...SECTION 5 MAINTENANCE ...
Page 131: ...NOTES ...
Page 132: ......