Released valve stem should automatically close and stop flow of air from the
tank.
If the valve stem resists returning to its position, then the whole drain
valve must be unscrewed and cleaned or replaced (if it is damaged) -
see section 5.3.5.
5.3.5 CLEANING THE DRAIN VALVE
DANGER
Release air from the air tank before dismantling drain valve.
Required maintenance activities:
Reduce pressure in air tank.
Reduction of pressure in tank is achieved by tilting the drain valve
stem.
Unscrew valve.
Clean valve, blow with compressed air.
Change copper seal.
Screw in valve, fill tank with air and check tank tightness.
Cleaning valve:
•
every 12 months (before winter period).
5.3.6 CLEANING AND MAINTAINING PNEUMATIC CONDUIT CONNECTIONS
AND PNEUMATIC SOCKETS
DANGER
Unreliable and dirty manure spreader connections may cause unreliability and faulty
functioning of braking system.