![Promise Technology VTRAK 15200 User Manual Download Page 63](http://html.mh-extra.com/html/promise-technology/vtrak-15200/vtrak-15200_user-manual_1617262063.webp)
Chapter 3: Setup
55
3.
Press Y and Enter to enable CHAP.
You return to the iSCSI Node Parameters menu.
4.
If you plan to use Bi-Directional (Mutual) CHAP, press 13 and Enter to
access BIDI CHAP Authentication.
Enable BIDI CHAP Authentication(y/n)?>
y
5.
Press Y and Enter to enable CHAP.
You return to the iSCSI Node Parameters menu.
6.
Press R and Enter to move back to the iSCSI Management menu.
Save iSCSI Node Parameters(y/n)?>
y
7.
Press Y and Enter to save the new parameters.
You return to the iSCSI Management menu.
8.
From the iSCSI Management menu, press 4 and Enter to access iSCSI
CHAP settings.
CHAP index Name
Secret
Attribute
-------------------------------------------------------------------------
0
TestInitiator 0123456789
Peer
-------------------------------------------------------------------------
iSCSI CHAP Record
1. Add
2. Delete
3. Edit
R. Return to Previous Menu
Please enter your menu choice>
9.
To add a CHAP record, press 1 and Enter.
Add a new CHAP record
Enter the name>
Peg Leg
Enter the secret>
9A8B7C6D
Peer(y/n)?>
y
New CHAP record added, press Enter key to return
10. Supply the information as prompted and press Enter after each item.
11. Press Enter to return to the iSCSI CHAP Record menu.
CHAP index Name
Secret
Attribute
-------------------------------------------------------------------------
0
PegLeg
9A8B7C6D
Peer
1
TestInitiator 0123456789
Peer
-------------------------------------------------------------------------