Data COMM Cable Replacement
Applies To: (Spinner®
Chrono
1
™ Power models only)
About
This procedure provides instruction to remove and install the Data COMM cable.
Data COMM cable routing
Starting from the console connection, the Data COMM cable enters and travels down the
handle bar post continuing down the inside of the right fork weldment exiting the lower cable
access hole located next to the upper edge of the cross member. The cable continues rear-
ward on the right side of the cross member crossing over to the left side connecting to the
LPCA
2
Data COMM cable port.
1
Spinner® Chrono™ Power bike.
2
Lower Printed Circuit Assembly board; also refered to as the Lower PCA or simply as the
lower board. On treadmills, it is the console to base function interface and the motor con-
troller unit (MCU). On self-powered units, it is the lower PCA console to base function inter-
face.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 72
5 Replacement Procedures
Data COMM Cable Replacement