![Precor SBK800-16 SPINNER Service Manual Download Page 123](http://html.mh-extra.com/html/precor/sbk800-16-spinner/sbk800-16-spinner_service-manual_1594855123.webp)
1. Remove the front and rear belt guard covers, see
"Belt Guard Cover Replacement"
2. Disconnect the battery cable Black wire from the Negative (-) battery terminal and
then the Red wire from the Positive (+) battery terminal, see
. Disconnect the battery Negative (-) terminal wire first:
3. Disconnect the battery cable
from the LPCA battery connector (J4) , see the fol-
lowing diagram. (If there is a LPCA moisture barrier
cable tie
installed, cut,
remove, and discard.)
4. If installed, cut the cable tie that secures the Mylar moisture barrier to the front of the
LPCA board.
5. Lift the Mylar moisture barrier and disconnect the Generator (J5) cable connector,
then the Data COMM (J3) cable connector and last the Strain Gauge (J1) cable con-
nector.
CAUTION
: Do not cut the Mylar moisture barrier to either remove or install the
strain gauge cable connector. Cutting the barrier will allow sweat and other fluids to
damage the LPCA board.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.