Page 37
11
Reconnect the Data cable, Auto Stop cable (Treadmill only), Stop Key
cable (Treadmill only), Heart Rate ground wire and the CSAFE cable
(if in use) from the Upper PCA
.
12
Reconnect the Heart Rate Cable to the Heart Rate PCA.
13
Replace the Heart Rate PCA. See
Replacing the P30 HR PCA
(on page 37).
14
Replace the access cover..
15
Tilt the console back against the mounting plated. While tilting the
console back feed the excess cable into weldment tube making sure
that the cables will not become pinched.
16
Fasten the console to the dash mounting plate with the four screws.
17
Fasten the dash transition cover using the two screws (TRM only)
18
Check treadmill operation per
Checking the AMT Operation
(on page 125).
Replacing the P30 HR PCA
1
Set the treadmill circuit breaker in the off position and unplug the
treadmill’s line cord from the AC outlet.
2
The PCA’s in the console are static sensitive. They can be damaged
if proper static prevention equipment is not used. Attach an anti-
static wrist strap to your arm, and then connect the ground lead of
the wrist strap to the treadmill’s frame ground.
3
Remove the HR PCA access panel on the back of the console.
Summary of Contents for AMT 823
Page 2: ......
Page 61: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 59...
Page 81: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 79...
Page 107: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 105...
Page 199: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 197...
Page 379: ...rfJ R BK BR Bl 0 d I w l 0 1 LO iftMotor...
Page 380: ......
Page 382: ......