© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 131
Procedure
1
Remove the gasket, top, front, rear, left and right side covers per
procedure,
Cover Replacement
(on page 152).
2
Place a belt gauge on the generator belt as shown in below.
Figure 52: Generator Belt
3
The belt gauge should read approximately 85 ±5 lbs. If the belt
tension is significantly high or low the belt tension may be
adjusted by loosening the generator mounting bolts.
4
Loosen or tighten the generator adjustment nut and bolt until the
belt gauge reads approximately 85 ±5 lbs.