Possible Remedies
6
Inspect power cord from wall plate to power supply (if non-
Treadmill) or patch panel (if Treadmill). Verify all connections
are tight and that there is no damage. Swap with known good cable,
if appropriate. Inspect connections from power supply to patch
panel (if non-Treadmill). Reconnect or replace all cables as
needed.
7
Open the machine and inspect the power cord running from patch panel
to console (if non-Treadmill) or from patch panel to power supply
(if Treadmill). Swap with known good to test, if needed. On
Treads, also check from power supply to console. Again, swap with
known good to test.
8
Inspect power supply for damage. Swap with known good power supply
to test. Replace, if needed.
9
Ensure that facility has configured their power correctly. About 8
non treadmill units can be connected through one dedicated circuit.
Each treadmill must be on a dedicated, branch circuit. Neutrals and
Hot Leads must not be shared among treadmills. If the power
supplied to the machines is not up to specification, the customer
will need to contact an electrician to make the needed repairs.
10
If the power, power supply, and power cabling are all good and
securely connected, the console will need to be replaced.
Summary of Contents for AMT 823
Page 2: ......
Page 61: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 59...
Page 81: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 79...
Page 107: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 105...
Page 199: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 197...
Page 379: ...rfJ R BK BR Bl 0 d I w l 0 1 LO iftMotor...
Page 380: ......
Page 382: ......