© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 137
Figure 58: Generator
17
Replace the main covers as per procedure,
Cover Replacement
(on page
152).
Calibrating the Incline Motor
Procedure
1
Remove the covers per procedure,
Cover Replacement
(on page 152).
Gas Shock Removal
2
Release tension from the top of the gas shock by pushing a # 1 flat
top screw driver in the slot under the tension clip. Do not
completely remove the retaining clip as it is difficult to
reinstall.
Tip: If the incline motor is jammed at full elevation, remove the lower retaining
clip to facilitate the gas shock removal.
3
Using another flat head screw driver as a pry bar, place the screw
driver head between the frame and the top of the gas shock and pry
the shock off the upper mounting stud.
4
Rotate the gas shock down and out of the way of the incline motor.