© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 147
S e c t i o n T e n
AMT Base Troubleshooting
Procedures
In This Section
Troubleshooting the Generator ......................
147
Troubleshooting the Incline System .................
148
Troubleshooting the Interconnect Cable .............
150
Troubleshooting the Generator
The generator performs three functions in the AMT. First, by
controlling the amount of electrical load applied to the generator, the
user’s pedaling resistance is controlled. Second, the generator is used
to charge the AMT’s internal battery. Lastly, one of the generators six
phase output windings is monitored to determine when the unit is in use
and when it is idle. This system also determines the stride rate by
determining the operating speed (output frequency) of the monitored
generator winding.
WARNING: Before continuing with this procedure, review the Warning and
Caution statements listed in the Warning and Caution Statements and
General Safety Guidelines Section, Things You Should Know.
1
Perform the generator resistance test per,
Measuring the Resistance of a
Generator
(on page 127). If any of the resistance measurements are
significantly high or significantly low, replace the generator.
Summary of Contents for AMT 823
Page 2: ......
Page 61: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 59...
Page 81: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 79...
Page 107: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 105...
Page 199: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 197...
Page 379: ...rfJ R BK BR Bl 0 d I w l 0 1 LO iftMotor...
Page 380: ......
Page 382: ......