© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 278
20
Lift the stairarms and then thread the flat belts over the flat belt
pulleys.
21
Select the QUICKSTART program and adjust the resistance
key until
resistance level 10 is displayed. Pedal the AMT for approximately
one minute, then recheck the belt tension.
Figure 216: Generator
22
The drive input belt tension should read approximately 135
±5
lbs
and the generator belt tension should read approximately 85 ±5 lbs.
See
Drive Belt Gauge Instructions
(on page 142)
23
Lift the stairarms and then thread the flat belts over the flat belt
pulleys.
24
Replace the covers as per procedure,
Cover Replacement
(on page 152).
Replacing the Generator
Procedure
1
Remove the covers as per procedure,
Cover Replacement
(on page 152).
2
Remove the lower PCA cover as per procedure,
Lower PCA Cover
(see
"
Removing the Lower PCA Cover
" on page 268).
Summary of Contents for AMT 823
Page 2: ......
Page 61: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 59...
Page 81: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 79...
Page 107: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 105...
Page 199: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 197...
Page 379: ...rfJ R BK BR Bl 0 d I w l 0 1 LO iftMotor...
Page 380: ......
Page 382: ......