Page 164
Top Cover Assembly
Important: In the following steps, do not apply excessive force to seat
the cover.
1
Position the rear edge of the top cover so that the clips on the top
and back covers are engaged securely.
2
Gently snap the front edge of the top cover into place, using the
heel of your hand if necessary.
3
Wrap the gasket around the center fame column below the heart rate
sensor grips, then fit it into the top cover. Make sure that the
surfaces and edges of the gasket are flush with those on the top
cover.
Replacing a Belt Guard
Finger Guard Replacement Procedure
Upper Arm Cover Removal
Figure 82: Upper Arm Covers
1
Remove the four screws that fasten the inside upper arm covers to
the upper arm.