5
Tighten the generator mounting bolts.
6
Select the QUICKSTART program and adjust the resistance
key until
resistance level 10 is displayed. Pedal the AMT for approximately
one minute, then recheck the belt tension.
7
The tension should read approximately 85 ±5 lbs.
Figure 53: Generator
Inspecting and Adjusting the Drive Input Belt Tension
WARNING: Before continuing with this procedure, review the Warning and
Caution statements listed in the Warning and Caution Statements and
General Safety Guidelines Section, Things You Should Know.
Procedure
1
Remove the gasket, top, front, rear, left and right side covers per,
Cover Replacement
(on page 152) Procedure .
2
Place a belt gauge to the drive input belt as shown below.