Function
Prog.
no.
Level
1)
Standard value
Pump modulation
None | Demand | Boiler setpoint |Temp differential nominal | Burner
output
2320
E
Demand
Pump speed min
2322
E
10%
Pump speed max
2323
E
100%
Output nominal
2330
E
30: 30 kW
40: 38 kW
60: 58 kW
80: 77 kW
95: 95 kW
115: 115 kW
Output basic stage
2331
E
30: 6 kW
40: 9 kW
60: 14 kW
80: 21 kW
95: 20 kW
115: 25 kW
Output at pump speed min
2334
E
0%
Output at pump speed max
2335
E
100%
Max fan output heating operation
2441
E
30: 30 kW
*)
40: 38 kW
*)
60: 58 kW
*)
80: 77 kW
*)
95: 95 kW
*)
115: 115 kW
*)
Max fan output heating full charging
2442
E
30: 30 kW
*)
40: 38 kW
*)
60: 58 kW
*)
80: 77 kW
*)
95: 95 kW
*)
115: 115 kW
*)
Fan output DHW max.
2444
E
30: 30 kW
*)
40: 38 kW
*)
60: 58 kW
*)
80: 77 kW
*)
95: 95 kW
*)
115: 115 kW
*)
Fan shutdown heating mode
Off | On
2445
E
Off
Fan shutdown delay
2446
E
3 s
Controller delay
Off | Heating mode only | DHW mode only | Heating and DHW mode
2450
E
Heating mode only
Fan output controller delay
2452
E
30: 10,0 kW
*)
40: 14,0 kW
*)
60: 22,5 kW
*)
80: 34,5 kW
*)
95: 36,0 kW
*)
115: 40,0 kW
*)
Controller delay duration
2453
E
40 s
Programming
54
Paramount three 30-115 kW
396532 05.11
Summary of Contents for Gas condensing boiler
Page 1: ...Installation operation and maintenance manual Gas condensing boiler Paramount three 30 115 kW ...
Page 21: ...Fig 5 Connection plan Prior to installation 396532 05 11 Paramount three 30 115 kW 21 ...
Page 24: ...4 8 Legend Prior to installation 24 Paramount three 30 115 kW 396532 05 11 ...
Page 133: ...Space for notes 396532 05 11 Paramount three 30 115 kW 133 ...
Page 134: ...Space for notes 134 Paramount three 30 115 kW 396532 05 11 ...
Page 135: ...Space for notes 396532 05 11 Paramount three 30 115 kW 135 ...