9940259 R02 - 2022
RZR
PRO R / PRO R 4 Service Manual
© Copyright Polaris Industries Inc.
1.39
SPN
COMPONENT
FMI
CONDITION
CODE
20
Data Drifted High
C1162
1888
PTO Solenoid Driver Circuit
3
Voltage Above Normal, Or Shorted To High Source
P1311
4
Voltage Below Normal, Or Shorted To Low Source
P1312
5
Current Below Normal Or Open Circuit
P1310
2584
Brake Pressure Switches
3
Voltage Above Normal, Or Shorted To High Source
C2244
4
Voltage Below Normal, Or Shorted To Low Source
C2044
13
Out Of Calibration
C1263
17
Data Valid But Below Normal Operating Range - Least Severe Level
C2144
20
Data Drifted High
C1164
2590
Vehicle Speed
16
Data Valid But Above Normal Operating Range - Moderately Severe
Level
P1500
2596
Speed Key Selected Maximum
Vehicle Speed Limit Message
19
Received Network Data In Error
U255A
31
Condition Exists
U2259
2629
Engine Turbocharger 1
Compressor Outlet Temperature
3
Voltage Above Normal, Or Shorted To High Source
P1235
4
Voltage Below Normal, Or Shorted To Low Source
P1236
3056
Oxygen Sensor Bank 1 Sensor 1
2
Data Erratic, Intermittent Or Incorrect
P0130
3
Voltage Above Normal, Or Shorted To High Source
P0132
4
Voltage Below Normal, Or Shorted To Low Source
P0131 / C1049
12
Bad Intelligent Device Or Component
P113A
17
Data Valid But Below Normal Operating Range - Least Severe Level
C2049
3057
Oxygen Sensor Bank 1 Sensor 2
2
Data Erratic, Intermittent Or Incorrect
P0136
3
Voltage Above Normal, Or Shorted To High Source
P0138
4
Voltage Below Normal, Or Shorted To Low Source
P0137
3597
ECU Output Supply Voltage 1
0
Data Valid But Above Normal Operational Range - Most Severe Level
P16A3
1
Data Valid But Below Normal Operational Range - Most Severe Level
P16A6
3
Voltage Above Normal, Or Shorted To High Source
P16A2
4
Voltage Below Normal, Or Shorted To Low Source
P16A1
16
Data Valid But Above Normal Operating Range - Moderately Severe
Level
P16A5
18
Data Valid But Below Normal Operating Range - Moderately Severe
Level
P16A7
3598
ECU Output Supply Voltage 2
0
Data Valid But Above Normal Operational Range - Most Severe Level
P16AA
1
Data Valid But Below Normal Operational Range - Most Severe Level
P16AC
3
Voltage Above Normal, Or Shorted To High Source
P16A9
4
Voltage Below Normal, Or Shorted To Low Source
P16A8
16
Data Valid But Above Normal Operating Range - Moderately Severe
Level
P16AB
18
Data Valid But Below Normal Operating Range - Moderately Severe
Level
P16AD
3599
ECU Output Supply Voltage 3
0
Data Valid But Above Normal Operational Range - Most Severe Level
P17AC
1
Data Valid But Below Normal Operational Range - Most Severe Level
P17AE
3
Voltage Above Normal, Or Shorted To High Source
P17AA
4
Voltage Below Normal, Or Shorted To Low Source
P17AB
16
Data Valid But Above Normal Operating Range - Moderately Severe
Level
P17AD