Do not interrupt gate movement (full opening/closing). In the even of the gate movement being interrupted, learning will
be resumed automatically during the next opening.
If the status light
flashes, resume the automatic wing movement path learning procedure (4 full opening and closing movements).
If the status light
keep flashing, see “Diagnostics”, page 49.
If the gate opens again after the closing movement is finished, loosen the wing fixtures and move them slightly towards the centre of the
gate.
After finishing the installation it is obligatory to check whether the obstacle detection system complies with the
specification provided in Annex A to the EN 12453 standard.
Setting the electronic control system standby/wake-up mode
After performing automatic learning, the electronic system switches automatically to standby mode after 5 minutes
if it receives no commands, in order to save power. In the standby mode all the status lights are off.
In order to check whether the driver is powered, or to check/change the setting, it is necessary to press and hold the
button for 2
seconds in order to wake the electronic system. The electronic system switches to standby mode automatically after 5 minutes if it
receives no commands.
Full gate closing and opening
The remote control devices delivered in the set are programmed. The procedure below enables programming
additional remote control devices.
Button No. 1