23. Setting the opening limiter
Push the button No. 1 of the remote control
device. After a few seconds, the first wing of
the gate will start opening slowly.
Push again the button No. 1 of the remote
control device in order to stop the gate wing in
the position desired.
Set the opening limiters in such a manner that their
bolt is in contract with the ball nut of the actuator,
and then tighten them using a hexagonal 3mm Allen
wrench (2 bolts per limiter).
Make 2 turns with the wrench after achieving the
contact point.
Push the button No. 1 of the remote
control device. The second wing of the
gate will open.
Push again the button No. 1 of the remote control
device in order to stop the gate wing in the
position desired.
Repeat setting the limiters for the second wing.