Gate type No.
5. Hold the position of the L and R connectors using a clamp.
The actuator mandrel is ejected to the maximum towards the internal
limiter when the closed gate adheres to the limiter in the ground.
View from
the
property
side
or
Mark the points for drilling
Mark the points for drilling
After applying the automatics to the gate, marker the points, and drill the openings, leaving the option of
further adjustment.
Drill the opening in the axis of longitudinal openings
using an 8.5 mm drill bit.
Ream the openings using a 10.5 mm drill bit from
the external side of the gate.