Preliminary electric wiring system
In order the install the gate drive it is necessary to:
•
Lead 230 V power supply to one of the posts located as close to the drive as possible.
•
Connect the posts with one another using a 2 x 1 mm2 cable that is not included in the set.
Other than that, it is necessary to obtain an IP55 distribution box for securing the connection between the cable going out from the drive
and the extension reaching the control module.
Obtain an Orange ICT Ø 25 mm sheath for underground cables.
If it is impossible to lead the cables underground between the posts, use a grommet that can withstand vehicle traffic.
Electronic
module
Middle rail
View
from
the
property side
Junction box (not
included in the set)
Flexible ICT sheath
2 x 1 mm
2
cable between the drives
2 x 0,75 mm
2
cable between the photocells
Using cables with a cross-section smaller than indicated in the manual may lead to voltage dips that may cause incorrect
functioning of motors.
1.
Power supply leading: 3 x 1,5 mm
2
cables for outdoor use
2.
24V connection between two drives: 2 x 1 mm
2
3.
Connection between photocells: 2 x 0.75 mm
2
Powering from mains
In order to ensure the functioning of the gate opening mechanism, it is necessary to connect 230 V - 50 Hz power supply to it. The
electric line has to be:
•
Intended solely for the gate opening mechanism.
•
Secured:
-
by means of a fuse or a 10 A circuit breaker,
-
by means of a residual current circuit breaker (30 mA).
•
Installed in line with safety standards for electrical systems valid in the country of use.
It is necessary to ensure the possibility of multipolar disconnection of power supply:
•
using a power supply cable featuring a plug,
•
or by mean of a switch that enables maintaining the distance between contacts of at least 3 mm at each pole (in line with the EN
60335-1 standard).
It is recommended to install a lightning current arrester (maximum residual voltage of 2 kV).