Page 3: ...ure totale et fermeture du portail 17 2 7 Détection d obstacle 17 3 Câblage des accessoires 18 3 1 Cellules photoélectriques selon le pack choisi 18 3 2 Feu orange selon le pack choisi 18 3 3 Batterie option 19 3 4 Antenne déportée option 19 3 5 Visiophone option 20 3 6 Contact à clé option 20 3 7 Eclairage de zone option 20 3 8 Alimentation solaire option 21 4 Paramétrages avancés 22 4 1 Ouvertur...

Page 4: ... de pose x 1 d Télécommande 2 touches x 2 e Jeu de cellules photoélectriques x 1 f Feu orange x 1 g Mnauel d installation et d utilisation x 1 Repère Désignation Qté h Fil de terre x 1 i Vis autoformeuse x 4 j Serre câble x 1 k Goujon x 4 l Cheville x 4 m Crayon Somfy x 1 n Vis capot x 1 o Joint torique x 1 p Cosse ronde isolée x 1 q Petite rondelle plate x 2 r Rondelle éventail x 2 s Rondelle pla...

Page 5: ...airage de zone B Feu orange selon pack choisi C Antenne D Barre palpeuse E Cellules photoélectriques selon pack choisi Repère Désignation F Butée fermeture G Butée ouverture H Moteur J Crémaillère Ce produit est destiné à la motorisation d un portail coulissant D une longueur max de 6 m et d un poids max de 400 kg en PVC bois ou métal pour une maison individuelle Encombrement accessoires en option...

Page 6: ...fermeture automatique du portail n est pas activée Clignote le paramètre fermeture automatique est sélectionnée E Voyant P1 Éteint le portail fonctionne en vitesse standard Clignote lentement le portail fonctionne en vitesse lente Clignote le paramètre vitesse du portail est sélectionné F Voyant RESET Allumé les réglages seuls ou les réglages et les points de commande radio sont effacés Clignote l...

Page 7: ...mm pour un usage extérieur type H07RN F mini Liaison des cellules câble 2 x 0 75 mm Autres accessoires voir page 6 Le passage du câble d alimentation doit être prévu suivant les normes électriques en vigueur dans le pays d utilisation Si la réalisation d une tranchée n est pas possible utiliser un passe câble qui pourra supporter le passage des véhicules réf 2400484 Passage des câbles Les câbles e...

Page 8: ...iliser du fil de section 0 3 mm exemple fil téléphonique au lieu du fil de section 0 75 mm ANT ANT BUS BUS 1 1 3 3 2 2 4 4 5 5 6 6 START ART M1 M1 M2 M2 11 11 13 13 10 10 12 12 BATT BATT LIGHT LIGHT 230V 230V 15 15 17 17 14 14 16 16 7 7 FLASH 8 8 9 9 24V L L N N TX RX 2 x 0 75 mm 2 x 0 75 mm 2 x 0 75 mm 2 x 0 75 mm 2 x 0 75 mm Câble coaxial 500 W max Alimentation secteur 230V 3 x 1 5 mm ou 3 x 2 5...

Page 9: ...00 SOMFY FR Fondations en béton Crémaillère 250 mm mini 200 mm mini Portail Portail Fondation Fondation Passage des câbles Crémaillère Les fondations en béton sur lesquelles sera fixé le moteur doivent respecter les cotes données sur le schéma ci dessous ...

Page 10: ...et pour acier PORTAIL PVC Le PVC est trop fragile pour fixer directement la crémaillère Les portails en PVC ont généralement un renfort en aluminium ou métallique ou une âme en acier se reporter à la ligne ci dessus Dans le cas où le portail PVC n a pas de renfort fixer un renfort métallique sur le portail à l endroit où sera fixée la crémaillère PORTAIL BOIS Vis à bois de diamètre 6 x 40 mm minim...

Page 11: ...es Retirer le capot du moteur Positionner le moteur sur les goujons veiller à ce que la bride embase du moteur se trouve à une hauteur maximum de 25 mm au dessus du sol L espace conseillé se situe entre 20 et 25 mm Une fois positionné en hauteur par rapport au sol fixer le moteur à l aide de 4 rondelles et de 4 écrous Positionner le passe fil pré percé dans l ouverture prévue pour le passage des c...

Page 12: ...il L utilisation d une crémaillère à fixation basse ref 9011089 est nécessaire Veuillez contacter Somfy D une main maintenir le crayon et de l autre main coulisser le portail pour marquer la position de la crémaillère Placer la crémaillère en alignant le haut de la crémaillère sur le trait tracé au crayon Fixer le premier élément de crémaillère Installer et fixer les autres éléments de la même faç...

Page 13: ...née du moteur vers le portail Le moteur est verrouillé Vérifier que le moteur est bien de niveau le portail coulisse correctement le pignon est bien entraîné le jeu crémaillère pignon de 2 mm ne varie pas trop Si ces conditions ne sont pas remplies régler la hauteur de la crémaillère Une fois toutes ces vérifications faites serrer les écrous pour fixer définitivement le moteur 1 3 Vérifier l insta...

Page 14: ...allation du moteur à droite du portail intervertir les fils branchés sur les bornes 10 et 11 de l électronique de commande étiquette verte M1 5 5 6 6 START ART M1 M1 M2 M2 11 11 13 13 10 10 12 12 BATT BATT 7 7 FLASH 8 8 9 9 24V Marron Bleu 5 5 6 6 START ART M1 M1 M2 M2 11 11 13 13 10 10 12 12 BATT BATT 7 7 FLASH 8 8 9 9 24V Marron Bleu Moteur à gauche Vue de l intérieur Moteur à droite Vue de l in...

Page 15: ...égainer le câble sur 150 mm 2 Recouper la phase et le neutre à 100 mm 3 Dénuder les 3 fils sur 8 mm 4 Sertir la cosse fournie sur le fil de terre jaune et vert 6 Brancher les fils comme indiqué dans le tableau Couleur fil Type Borne Commentaires Bleu Neutre 17 Marron Noir Rouge Phase 16 Jaune et Vert Terre Visser une rondelle plate la cosse du fil de terre de l alimentation serti à l étape 4 et un...

Page 16: ...oteur 1 8 Position de l antenne de l électronique de commande 1 7 Raccorder l électronique de commande à la terre 1 Raccorder le fil de terre fourni en haut à droite de l électronique de commande 2 Visser une rondelle plate la cosse du fil de terre et une rondelle éventail avec une vis sur le haut du moteur ...

Page 17: ...erme à nouveau Le voyant s allume fixe L auto apprentissage est réussi et le moteur est opérationnel Si le voyant clignote 2 fois recommencer l auto apprentissage Le portail doit être fermé à la fin de l auto apprentissage Si le portail est ouvert voir encadré IMPORTANT ci dessous Pendant l auto apprentissage un appui sur la touche 1 de la télécommande ou sur le bouton de l électronique de command...

Page 18: ...tures trous oblongs ouvertures pour le passage des câbles à l aide de silicone Lorsque l auto apprentissage a été effectué l électronique passe automatiquement en veille après 5 minutes d inactivité pour faire des économies d énergie En état de veille tous les voyants sont éteints Il est fortement conseillé de boucher toutes les ouvertures pour éviter les court circuits provoqués par des insectes ...

Page 19: ...meture du portail 2 7 Détection d obstacle Portail fermé appuyer sur la touche 1 de la télécommande pour ouvrir totalement le portail Portail en mouvement appuyer sur la touche 1 de la télécommande pour arrêter le portail Portail ouvert appuyer sur la touche 1 de la télécommande pour fermer le portail Les télécommandes livrées dans le kit sont déjà mémorisées et programmées pour que la touche 1 de...

Page 20: ...ture du portail Les cellules photoélectriques sont reconnues par l électronique de commande à la fin de ce mouvement Fonctionnement avec des cellules photoélectriques Si les cellules sont occultées pendant la fermeture du portail le portail s arrête et se ré ouvre Ampoule 10 W 24 V MAXIMUM L utilisation d ampoule de puissance supérieure à 10 W 24 V peut provoquer des dysfonctionnements de la motor...

Page 21: ... fonctionne sur batterie Pour augmenter l autonomie de la batterie en fonctionnement les commandes filaires sont désactivées seuls les télécommandes et points de commande radio permettent de commander le portail Pour une durée de vie optimale de la batterie couper l alimentation électrique du portail au moins 3 fois par an pour le faire fonctionner quelques cycles sur la batterie 3 4 Antenne dépor...

Page 22: ...ncompatible avec une alimentation solaire Cet accessoire est incompatible avec une alimentation solaire 3 6 Contact à clé option 3 7 Eclairage de zone option Cet accessoire est incompatible avec une alimentation solaire Utilisez uniquement des ampoules halogènes ou incandescences pour l éclairage de zone 500 W maximum ...

Page 23: ... branché à une alimentation solaire le boîtier électronique du moteur risquerait d être endommagé Lorsque le moteur fonctionne sur l alimentation solaire seuls les télécommandes et points de commande radio permettent de commander le portail les commandes filaires sont désactivées les accessoires de sécurité filaires restent activés cellules photoélectriques feu orange ...

Page 24: ...ions 1 2 3 2s 0 5s 0 5s Appuyer 2 s sur le bouton de l électronique de commande Le voyant s allume Poser la télécommande sur la cible de l électronique de commande Appuyer sur la touche 2 de la télécommande Les voyants RADIO et s allument puis s éteignent L ouverture piétonne est activée sur cette touche Activer l ouverture piétonne Fonctionnement de l ouverture piétonne Répéter la procédure Activ...

Page 25: ...e de commande du moteur 1 2 3 2s x3 2s 2s Appuyer 2 s sur le bouton de l électronique de commande Le voyant s allume Poser la télécommande sur la cible de l électronique de commande Rester appuyé sur la touche 1 de la télécommande jusqu à ce que le voyant clignote Activer la fermeture automatique Fonctionnement de la fermeture automatique Appuyer sur la touche 1 de la télécommande pour ouvrir le p...

Page 26: ...r la télécommande sur la cible de l électronique de commande Rester appuyé sur la touche 1 de la télécommande jusqu à ce que le voyant clignote 4 5 6 2s x3 2s x3 Appuyer sur la touche 2 de la télécommande Le voyant clignote Appuyer 3 fois sur la touche 1 de la télécommande Le voyant est éteint La fermeture automatique est désactivée Désactiver la fermeture automatique ...

Page 27: ...s utilisateurs par exemple écrasés par le portail Pour satisfaire à l exigence de la norme EN 12453 il est impératif de respecter les contraintes du domaine d application 4 3 Vitesse du portail Par défaut le portail fonctionne en vitesse standard 1 2 3 4 5 2s x2 x2 x1 2s x2 x2 x1 2s x2 x2 x1 2s x2 x2 x1 2s Appuyer 2 s sur le bouton de l électronique de commande Le voyant s allume Poser la télécomm...

Page 28: ... 2s x2 x2 x1 2 2s x2 x2 x1 2s x1 3 Appuyer 2 s sur le bouton de l électronique de commande Le voyant s allume Poser la télécommande sur la cible de l électronique de commande Rester appuyé sur la touche 1 de la télécommande jusqu à ce que le voyant clignote x2 x2 x1 4 2s x2 x2 x1 x1 5 2s x2 x2 x1 x1 6 Appuyer une fois sur la touche 1 de la télécommande Le voyant P1 clignote Appuyer une fois sur la...

Page 29: ...rtail compte pour 2 points de commande Si vous mémorisez un 17ème point de commande le premier mémorisé sera automatiquement effacé Touche 1 Touche 2 Possibilité 1 Ouverture totale Ouverture piétonne ou autre automatisme Somfy RTS Possibilité 2 Autre équipement Somfy RTS Ouverture totale Possibilités de programmation de la télécommande 2 touches Si vous souhaitez programmer une ouverture piétonne ...

Page 30: ...uverture totale Ouverture piétonne ou autre automatisme Somfy RTS Possibilité 4 Autre automatisme Somfy RTS Autre automatisme Somfy RTS Autre automatisme Somfy RTS Ouverture totale Possibilités de programmation de la télécommande 4 touches Ouverture Stop Fermeture Pour ouvrir complètement le portail appuyer sur la touche Montée de la télécommande Pour arrêter le portail en cours de mouvement appuy...

Page 31: ...s allume puis s éteint lorsque la touche de la télécommande est relâchée La télécommande est mémorisée Télécommande 3 touches Télécommande 2 ou 4 touches 5 3 Supprimer les télécommandes 1 2 3 2s 0 5s 0 5s Appuyer 2 s sur le bouton de l électronique de commande Le voyant s allume Poser la nouvelle télécommande à programmer sur la cible de l électronique de commande Faire un appui bref sur la touche...

Page 32: ...er le capot Retirer la pile à l aide d un tournevis Remplacer la pile 3 V CR 2430 6 2 Changer la pile de la télécommande 6 1 Assistance Si la panne persiste ou pour tout autre problème ou demande de renseignement sur votre motorisation rendez vous sur notre Forum d entraide forum somfy fr La communauté est là pour vous répondre et la réponse à votre question y figure peut être déjà Vous pouvez éga...

Page 33: ...es télécommandes points de commande mémorisés 6 x2 Rester appuyé sur la touche 2 de la télécommande jusqu à ce que le voyant RESET s allume 6 Rester appuyé sur la touche 2 de la télécommande jusqu à ce que tous les voyants s allument 7 x2 Le voyant clignote 2 fois voir 15 pour lancer un auto apprentissage Course du portail désactivation des paramètres 6 3 Effacer les réglages Dans quels cas efface...

Page 34: ...e 1 clignotement Fonctionnement sur batterie de secours Vérifier l alimentation secteur 2 clignotements Moteur en attente d apprentissage de la course du portail Lancer l auto apprentissage voir page 15 3 clignotements Cellules photoélectriques en défaut Vérifier qu il n y a pas d obstacle entre les cellules Vérifier l alignement des cellules Vérifier le câblage des cellules voir page 18 4 clignot...

Page 35: ...tique Conforme à la norme EN 12 453 Température de fonctionnement 20 C à 60 C Protection thermique Oui Indice de protection IP 44 Récepteur radio intégré Oui Télécommandes Fréquence radio 433 42 MHz 10 mW Portée en champ d usage 30 m Quantité mémorisable 16 Connexions possibles Sortie pour feu orange Clignotante 24 V 10 W maximum Sortie éclairage 500 W maxi en 230 V halogène ou incandescence uniqu...

Page 36: ......

Page 37: ...16 2 6 Fully opening and closing the gate 17 2 7 Obstacle detection 17 3 Wiring the accessories 18 3 1 Photoelectric cells depending on the pack chosen 18 3 2 Orange light depending on the pack chosen 18 3 3 Battery optional 19 3 4 Offset aerial optional 19 3 5 Videophone optional 20 3 6 Key lock optional 20 3 7 Area lighting optional 20 3 8 Solar power optional 21 4 Advanced parameter settings 22...

Page 38: ...ion template x 1 d 2 button remote control x 2 e Set of photoelectric cells x 1 f Orange light x 1 g Installation and operating guide x 1 Mark Designation Qty h Earth wire x 1 i Self drilling screw x 4 j Cable clamp x 1 k Stud x 4 l Plug x 4 m Somfy pencil x 1 n Cover screw x 1 o O ring x 1 p Insulated round terminal x 1 q Small flat washer x 2 r Star washer x 2 s Flat washer x 8 t NUT x 8 dependi...

Page 39: ...lighting B Orange light depending on the pack chosen C Aerial D Safety edge E Photoelectric cells depending on the pack chosen Mark Designation F Closing end stop G Opening end stop H Motor J Rack This product is intended for the motorisation of a sliding gate with a max length of 6 m and a max weight of 400 kg in PVC wood or metal for a detached house Space requirements optional accessories ...

Page 40: ...gate is activated OFF automatic closure of the gate is not activated Flashing the automatic closure parameter is selected E Indicator light P1 OFF the gate operates at standard speed Slowly flashing the gate operates at slow speed Flashing the gate speed parameter is selected F RESET indicator light On the settings alone or the settings and the radio control points are deleted Flashing the setting...

Page 41: ... or 3 x 2 5 mm for outdoor use type H07RN F minimum Linking of cells 2 x 0 75 mm cable Other accessories see page 6 Provision must be made for the supply cable to be fed through according to the electrical standards in force in the country of use If a cable conduit cannot be made use a cable grommet which will withstand the passage of vehicles ref 2400484 Cable feed Underground cables must be equi...

Page 42: ...ross section may be used example telephone cable instead of wire with a cross section of 0 75 mm ANT ANT BUS BUS 1 1 3 3 2 2 4 4 5 5 6 6 START ART M1 M1 M2 M2 11 11 13 13 10 10 12 12 BATT BATT LIGHT LIGHT 230V 230V 15 15 17 17 14 14 16 16 7 7 FLASH 8 8 9 9 24V L L N N TX RX 2 x 0 75 mm 2 x 0 75 mm 2 x 0 75 mm 2 x 0 75 mm 2 x 0 75 mm coaxial cable 500 W max 230V power supply 3 x 1 5 mm or 3 x 2 5 m...

Page 43: ...and operating guide SOMFY EN Concrete base Crémaillère 250 mm mini 200 mm mini Gate Gate Base Base Cable feed Rack The concrete base on which the motor will be installed must comply with the dimensions indicated on the diagram below ...

Page 44: ...Socket wrench no 10 5 mm with a drill for steel PVC GATE PVC is tool fragile to fasten the rack and pinion directly PVC gates generally have an aluminium or metallic brace or a steel core see the line above If a PVC gate does not have a brace fasten a metallic brace to the gate where the rack and pinion will be fastened WOODEN GATE Wood screws diameter 6 x 40 mm minimum washer Socket wrench no 10 ...

Page 45: ...ds Tighten 4 nuts and 4 washers Remove the motor cover Position the motor on the studs ensure that the bracket base of the motor is no more than 25 mm above the ground The recommended space is between 20 and 25 mm Once the motor is positioned at the right height in relation to the ground fix it in place using the 4 washers and 4 nuts Position the pre drilled grommet in the opening provided for the...

Page 46: ...w fastening rack ref 9011089 must be used Please contact Somfy With one hand hold the pencil in the notches provided on the motor and with the other hand slide the gate to mark the fastening height of the rack Position the rack by aligning the top of the rack with the line drawn in pencil Fasten the first item of the rack Install and fasten the other items in the same way interlocking them with th...

Page 47: ...s the gate The motor is locked Check that the motor is level the gate runs correctly the pinion is correctly driven the 2 mm clearance between the rack and pinion does not vary significantly If these conditions are not satisfied adjust the height of the rack Once all these checks have been completed tighten the nuts to fasten the motor permanently 1 3 Checking the installation of the motor ...

Page 48: ...o install the motor to the right of the gate switch the wires connected to terminals 10 and 11 of the control electronics green M1 label 5 5 6 6 START ART M1 M1 M2 M2 11 11 13 13 10 10 12 12 BATT BATT 7 7 FLASH 8 8 9 9 24V Brown Blue 5 5 6 6 START ART M1 M1 M2 M2 11 11 13 13 10 10 12 12 BATT BATT 7 7 FLASH 8 8 9 9 24V Brown Blue Motor on left hand side View from inside Motor on right hand side Vie...

Page 49: ...e over a distance of 150 mm 2 Overlap the live and neutral wires at 100 mm 3 Strip the 3 wires over a distance of 8 mm 4 Crimp the terminal provided on the earth wire yellow and green 6 Connect the wires as shown in the table Wire colour Type Terminal Comments Blue Neutral 17 Brown black red Live 16 Yellow and green Earth Tighten a flat washer the power supply earth terminal crimped in step 4 and ...

Page 50: ... top of the motor 1 8 Position of the control electronics aerial 1 7 Earthing the control electronics 1 Connect the earth wire supplied to the top right of the control electronics 2 Tighten a flat washer the earth wire terminal and a star washer using a screw to the top of the motor ...

Page 51: ...icator light is lit constantly Self learning has been successfully completed and the motor is operational If the indicator light flashes twice begin the self learning process again The gate must be closed once self learning is complete If the gate is open see the IMPORTANT box below During the self learning process pressing button 1 on the remote control or the button on the control electronics ca...

Page 52: ...ugh plug the openings oblong holes cable feed openings using silicone Once the self learning process has been completed the electronics automatically switch to standby after 5 minutes of inactivity to save energy In standby mode all indicator lights are switched off You are strongly advised to plug all the openings to avoid short circuits caused by insects 2 5 Lifting the cover 2 1 1 Place the cov...

Page 53: ...pening and closing the gate 2 7 Obstacle detection Gate closed press button 1 on the remote control to open the gate to the full Gate moving press button 1 on the remote control to stop the gate Gate open press button 1 on the remote control to close the gate The remote controls supplied with the kit are already memorised and programmed so that button 1 on the remote controls activates full openin...

Page 54: ...gain start a gate opening or closing procedure The photoelectric cells are recognised by the control electronics once this movement is complete Operation with photoelectric cells If the cells are blocked when closing the gate the gate will stop and reopen 10 W 24 V bulb MAXIMUM use of a bulb with power greater than 10 W 24 V can cause motorisation malfunctions 3 2 Orange light depending on the pac...

Page 55: ...ttery operated To increase the operation time of the battery during use the wired controls are deactivated and the gate can only be controlled using the remote controls and the radio control points To optimise the service life of the battery cut the electrical power to the gate at least 3 times a year and run a few cycles using the battery 3 4 Offset aerial optional The offset aerial is connected ...

Page 56: ...ional NC COM NO This accessory is not compatible with solar power This accessory is not compatible with solar power 3 6 Key lock optional 3 7 Area lighting optional This accessory is not compatible with solar power Only use halogen or incandescent bulbs for area lighting 500 W maximum ...

Page 57: ...pply when it is connected to a solar power supply as this may damage the motor s electronics unit When the motor is running on the solar feed only the remote controls and radio control points can be used to control the gate wired controls are deactivated the wired safety accessories photoelectric cells orange light remain active ...

Page 58: ...n the button of the control electronics for 2 seconds The indicator light comes on Position the remote control on the control electronics target Press button 2 on the remote control The RADIO and indicator lights come on then go out The pedestrian opening is activated on this button Activating the pedestrian opening Pedestrian opening operation Repeat the Activate pedestrian opening procedure usin...

Page 59: ...ted and recognised by the motor s control electronics 1 2 3 2s x3 2s 2s Press on the button of the control electronics for 2 seconds The indicator light comes on Position the remote control on the control electronics target Keep button 1 of the remote control depressed until the indicator light flashes Activating automatic closing Automatic closure operation Press button 1 on the remote control to...

Page 60: ...es on Position the remote control on the control electronics target Keep button 1 of the remote control depressed until the indicator light flashes 4 5 6 2s x3 2s x3 Press button 2 on the remote control The indicator light flashes Press button 1 on the remote control 3 times The indicator light is off Automatic closing is deactivated Deactivating automatic closing ...

Page 61: ...users for example by being crushed by the gate To meet the requirements of standard EN 12453 it is essential to comply with the field of application constraints 4 3 Gate speed By default the gate operates at standard speed 1 2 3 4 5 2s x2 x2 x1 2s x2 x2 x1 2s x2 x2 x1 2s x2 x2 x1 2s Press the button on the control electronics for 2 seconds The indicator light comes on Position the remote control o...

Page 62: ... x2 x2 x1 2s x1 3 Press the button on the control electronics for 2 seconds The indicator light comes on Position the remote control on the control electronics target Keep button 1 of the remote control depressed until the indicator light flashes x2 x2 x1 4 2s x2 x2 x1 x1 5 2s x2 x2 x1 x1 6 Press button 1 on the remote control once Indicator light P1 flashes Press button 2 on the remote control on...

Page 63: ...e counts as 2 control points If you memorise a 17th control point the first point memorised will automatically be deleted Button 1 Button 2 Possibility 1 Complete opening Pedestrian opening or other Somfy RTS automatism Possibility 2 Another Somfy RTS device Complete opening Possibilities for programming the 2 button remote control If you wish to programme a pedestrian opening it must be programme...

Page 64: ...sm Another Somfy RTS automatism Complete opening Pedestrian opening or other Somfy RTS automatism Possibility 4 Another Somfy RTS automatism Another Somfy RTS automatism Another Somfy RTS automatism Complete opening Possibilities for programming the 4 button remote control Opening Stop Closing To open the gate completely press the Up button on the remote control To stop the gate while it is moving...

Page 65: ...e on then go out when you release the button on the remote control The remote control has been memorised 3 button remote control 2 or 4 button remote control 5 3 Deleting a remote control 1 2 3 2s 0 5s 0 5s Press the button on the control electronics for 2 seconds The indicator light comes on Position the new remote control to be programmed on the control electronics target Briefly press the butto...

Page 66: ... Insert the screwdriver in the slot and lift the cover Remove the battery using a screwdriver Replace the battery 3 V CR 2430 6 2 Replacing the remote control battery 6 1 Assistance Despite the care taken in the design of our products and the creation of our guides you may encounter difficulties during the installation of your automatic control device or have some unanswered questions Do not hesit...

Page 67: ...settings To clear the settings and the memorised remote controls control points 6 x2 Keep button 2 of the remote control depressed until the RESET indicator light comes on 6 Keep button 2 of the remote control depressed until the all the indicator lights come on 7 x2 The indicator light flashes twice see 15 to run a self learning procedure Gate travel deactivation of the settings 6 3 Clear the set...

Page 68: ...r light of the electronics unit is flashing 1 flash Operation using the backup battery Check the mains power supply 2 flashes Motor waiting for gate travel to be programmed Start self learning procedure see page 15 3 flashes Faulty photoelectric cells Check that there is nothing obstructing the cells Check cell alignment Check the cell wiring see page 18 4 flashes Short circuit of electronic unit ...

Page 69: ...atic obstacle detection Compliant with standard EN 12 453 Operating temperature 20 C to 60 C Thermal protection Yes Protection rating IP 44 Integrated radio receiver Yes Remote controls Radio frequency 433 42 MHz 10 mW Range in field of use 30 m Storage quantity 16 Possible connections Output for orange light Flashing 24 V 10 W maximum Lighting output 500 W max with 230 V halogen or incandescent o...

Page 70: ...34 EN FREEVIA 400 installation and operating guide SOMFY EN ...

Page 71: ...35 EN FREEVIA 400 installation and operating guide SOMFY EN ...

Page 72: ...omfy Sp z o o Somfy LLC Russia Somfy Italia SRL Somfy España SA Somfy Portugal Somfy Hellas SA 0 820 055 055 0 15 la minute Forum d entraide forum somfy fr 07472 930 495 www somfy de 023 56 23 752 www somfy nl 02 712 07 70 www somfy be 44 0113 391 3030 www somfy co uk 900 20 68 68 www somfy es 808100153 www somfy pt 211 6000 222 www somfy gr 810377199 www somfy pl 8 800 555 60 70 www somfy ru diy ...