background image

PRODUCT MANUAL

6

beamLabs.io

Summary of Contents for 2211-U

Page 1: ...PRODUCT MANUAL 6 beamLabs io ...

Page 2: ...er 8 Mounting Header Bracket 9 Attaching Rail and Mounting Door Bracket 10 Mounting Power Head to Ceiling 11 Attaching Door Arms 12 Emergency Release Handle 13 Connecting Photo Eye Safety System 14 Connecting Power and Aligning Photo Eye Safety System 15 Connecting Deluxe Door Control 16 Enabling Disabling Motion Sensing Security Lighting 17 Connecting Standard Door Control 18 Travel Limit Adjustm...

Page 3: ...beamLabs io 1 800 436 9186 1 CARTON CONTENTS BSBHF PPS 0QFOFS 6 Clevis Pin Lag Screw 5 16 1 1 2 Bolt 5 16 18x1 Hitch Pin Anchors Flange Nut Self Threading Screw 1 4 x 5 8 ...

Page 4: ... floor and avoiding con tact with vehicles to avoid accidental release 5 Do not connect the opener to source of power until instructed to do so 6 Locate the control button a within sight of door b at a minimum height of 5 feet so small children are not able to reach it and c away from all moving parts of the door 7 Install the Entrapment Warning Label next to the wall mount control button in a prom...

Page 5: ...installation To test your garage door 1 Raise and lower the door to check if there is any sticking or binding 2 Check for loose hinges damaged rollers frayed cables and damaged or broken springs 3 Lift the door approximately halfway and release The door should stay at that point under proper spring tension Call a qualified garage door service technician if your door binds sticks or is unbalanced St...

Page 6: ...pply additional force tap gently on the end of the rail with a rubber mallet or on padded flooring Rail Middle Segment Right Wrong Loosely connected Rail Header Segment 3BJM M FBEFS 4FHNFOU 3BJM 3BJM JEEMF 4FHNFOUT Y 3BJM OE 4FHNFOU OE 4FHNF 4UPQ PMU 4UPQ PMU ed Rail Header Segment Securely connected by applying force Rail Header Segment Rail Middle Segments x3 Rail End Segment Stop Bolt ...

Page 7: ...6 Opener Carton Clevis Pin 3 8 x 1 3 4 Hitch Pin Use garage door opener carton to assemble rail to power head Use packing material as protective base for power head Align and slide rail into rail bracket as shown Insert clevis pin into rail bracket as shown Insert hitch pin into clevis pin as shown BSBHF PPS 0QFOFS 6 p U ...

Page 8: ...n Insert pulley into the rail slot Insert clevis pin through rail hole and pulley Insert hitch pin into clevis pin TROLLEY AND PULLEY ASSEMBLY Look in the box for Trolley Pulley Slide Trolley onto the rail Make sure the arrow on the trolley points toward the door ...

Page 9: ...S INJURY DO NOT connect power until instructed Keep hands and fingers clear from sprocket during operation Wear gloves when installing chain and cable Keep hands and fingers away from joints and possible sharp edges Insert cable through circular hole in trolley Pull cable through pulley slot and toward power head Pull trolley lock lever down to unlock Insert trolley shaft into trolley Lock trolley s...

Page 10: ... to cable connector on trolley shaft until chain is about 1 4 inch 64 cm above the base of rail Chain to cable connector Self Threading Screw 1 4 x 5 8 Flange Nut Attach sprocket cover to power head Fasten rear tab with flange nut on top of steel chassis Fasten front tab with self threading screws to hole on top of steel chassis G Tighten until 1 4 inch 64 cm ...

Page 11: ...when required DO NOT install the header bracket over drywall Concrete anchors MUST be used when mounting the header bracket into masonry NEVER try to loosen move or adjust garage door springs cables pulleys brackets or hardware Contact a qualified garage door service technician if your door binds sticks or is unbalanced An unbalanced door might not reverse when required Take a level measure and mar...

Page 12: ...d secure with hitch pin Position door bracket on centerline of the top garage door panel Door bracket should be 2 4 inches 5 10 cm below the top edge of door panel Center Line Hitch Pin Clevis Pin 3 8 x 1 3 4 Door Bracket 2 x Self Threading Screw 1 4 x 5 8 CAUTION To prevent SERIOUS INJURY DO NOT connect power until instructed REINFORCEMENT is recommended for fiberglass aluminum or lightweight stee...

Page 13: ...ckets to masonry concrete anchors not provided MUST be used 4 x Lag Screw 5 16 x 1 1 2 4 x Bolt 5 16 18 x 1 4 x Flange Nut Hanging Brackets not supplied Fasten angle iron to stud under a finished ceiling Raise power head to measure distance from each side rail must be horizontal Cut both hanging brackets to appropriate length Secure opener from each side to hanging brackets with 5 16 x 1 bolt Raise...

Page 14: ...ands and fingers away from joints and possible sharp edges Close your garage door and disengage trolley Fasten curved door arm to the door bracket with 5 16 x 1 clevis pin and secure with hitch pin Fasten straight door arm to trolley with a 5 16 x 1 clevis pin and secure with hitch pin Attached door arms fasten with two 5 16 bolts and flange nuts Bring straight and curved door arm together Find two ...

Page 15: ...r hand knot Thread end of the rope through hole in trolley lever Measure rope length so the handle is 6 feet 183 cm above the floor and is clear from the top of your vehicle Secure with a overhand knot Hole in Trolley Lever WARNING To prevent SERIOUS INJURY In case of power outage or door obstruction PULL EMERGENCY HANDLE to release door from opener When trolley is disengaged trolley level pointing...

Page 16: ...e tab Connect wires to power head VERY IMPORTANT Strip 7 16 inch 1 cm of insulation from the end of the wire Each pair of terminals MUST be connected with one white wire and one striped wire non polarized from the SAME accessory Door track mounting Floor mounting WARNING To prevent SERIOUS INJURY or DEATH from electrocution Power MUST NOT be connected until instructed The garage door opener will n...

Page 17: ...H from a closing garage door The photo eye safety system MUST be installed BEFORE connecting power The photo eye safety system MUST be properly connected and aligned BEFORE operating the opener When the photo eye safety system is properly aligned green LED emitter will emit a steady green light and the red LED sensor will emit a steady red light The path of the invisible light beam MUST NOT be obs...

Page 18: ... connect power until instructed install the garage door opener at least 7 feet 2 13 m above the floor Fasten the power head SECURELY to STRUCTURAL SUPPORTS of the garage to prevent falling If installing brackets to masonry concrete anchors not provided MUST be used Deluxe Door Control 2x Screw 6 x 1 3 8 Connect plug from deluxe door control to wall panel outlet on the back panel of the power head I...

Page 19: ...rity lighting will remain illuminated for 4 5 minutes or for as long as there is motion in the garage To deactivate motion sensing Press and hold LIGHT button for 2 seconds The power head will beep once to indicate motion sensing has been deactivated To active motion sensing Press and hold LIGHT button for 2 seconds The power head will beep 3x to indicate motion sensing has been activated MOTION A...

Page 20: ...d Install the opener at least 7 feet 2 13m above the floor Fasten the power head SECURELY to STRUCTURAL SUPPORTS of the garage to prevent falling If installing brackets to masonry concrete anchors not provided MUST be used Standard Door Control 2x Screw 6 x 1 3 8 Min 5 1 52 m above floor Standard Door Control 2x Screw 6 x 1 3 8 2x Drywall Anchors New Image 1 Strip 7 16 inch 11 mm of insulation from ...

Page 21: ...ANNOT adjust force manually to compensate for binding or sticking of the garage door Call a qualified garage door service person to make necessary adjustments in case of binding YOU CANNOT manually increase the force required for closing the door After ANY adjustments Safety Reverse Test MUST be performed to ensure the door reverses on contact with a 1 5 inch 3 8 cm high object 2x4 laid flat Press a...

Page 22: ...t is set WARNING To prevent SERIOUS INJURY or DEATH from improper Force Adjustment YOU CANNOT adjust force manually to compensate for binding or sticking of the garage door Call a qualified garage door service person to make necessary adjustments in case of binding YOU CANNOT manually increase the force required for closing the door After ANY adjustments Safety Reverse Test MUST be performed to ens...

Page 23: ... Setting is completed Flash and 2 beeps WARNING To prevent SERIOUS INJURY or DEATH from improper Force Adjustment YOU CANNOT adjust force manually to compensate for binding or sticking of the garage door Call a qualified garage door service person to make necessary adjustments in case of binding YOU CANNOT manually increase the force required for closing the door After ANY adjustments Safety Revers...

Page 24: ...ing operation and or testing After ANY adjustments to the door system the Safety Reverse Test MUST be performed to ensure the door reverses on contact with a 1 1 2 inch 3 8 cm thick 2x4 laid flat object The Photo Eye Safety System MUST be properly aligned and tested regularly Place a 1 1 2 inch 3 8cm flat solid object on the floor centered under the garage door Use Door Control to close door Door MUS...

Page 25: ...beamLabs io 1 800 436 9186 SPARE PARTS B C JUDI 1JO 4FMG 5ISFBEJOH 4DSFX MBOHF VU MFWJT 1JO BH 4DSFX PMU ODIPS 05 PU WBJMBCMF BT JOEJWJEVBM QBSUT ...

Page 26: ...EOH IRU FRPSOLDQFH FRXOG YRLG WKH XVHU V DXWKRULW WR RSHUDWH WKH HTXLSPHQW 7KLV GHYLFH FRPSOLHV ZLWK SDUW RI WKH 5XOHV 2SHUDWLRQ LV VXEMHFW WR WKH IROORZLQJ WZR FRQGLWLRQV 7KLV GHYLFH PD QRW FDXVH KDUPIXO LQWHUIHUHQFH DQG WKLV GHYLFH PXVW DFFHSW DQ LQWHUIHUHQFH UHFHLYHG LQFOXGLQJ LQWHUIHUHQFH WKDW PD FDXVH XQGHVLUHG RSHUDWLRQ ...