User’s Manual of MGSD-10080F
572
<group-id> : protection group-id for which vid belongs to.
Syntax:
Erps vlan add <vid> <group-id>
Parameters:
<vid>
: VLAN ID (1-4095)
<group-id>
: protection group id 1 - 64
ERPS VLAN Delete
Description:
Disassociating a given vlan to a protection group
<vid> : protected vlan to be deleted
<group-id> : protection group-id for which vid belongs to.
Syntax:
Erps vlan delete <vid> <group-id>
Parameters:
<vid>
: VLAN ID (1-4095)
<group-id>
: protection group id 1 - 64
ERPS MEP
Description:
Associating Port 0/1 MEP to a protection group
<east_sf_mep> : Mep_ID for finding out Continuity Check errors on Port 0
<west_sf_mep> : Mep_ID for finding out Continuity Check errors on Port 1
<east_raps_mep> : Mep_ID for transmitting R-APS frames on Port 0
<west_raps_mep> : Mep_ID for transmitting R-APS frames on Port 1
<group_id> : protection group id for which mep is associating.
Syntax:
Erps mep <east_sf_mep> <west_sf_mep> <east_raps_mep> <west_raps_mep> <group-id>
Parameters:
<east_sf_mep>
: SF mep id for Port 0
Summary of Contents for MGSD-10080F
Page 1: ...User s Manual of MGSD 10080F 1 ...
Page 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Page 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Page 358: ...User s Manual of MGSD 10080F 358 ...
Page 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Page 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Page 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Page 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...