User’s Manual of MGSD-10080F
48
MGB-LB40
SFP-Port 1000Base-L X ( W DM,TX:1550nm) mini-GBIC module-40km
MGB-TSX
SFP-Port 1000Base-SX mini-GBIC module - 550m (-40~75 degrees C)
MGB-TLX
SFP-Port 1000Base-LX mini-GBIC module - 10km (-40~75 degreesC)
MGB-TL30
SFP-Port 1000Base-LX mini-GBIC module - 30km (-40~75 degrees C)
MGB-TL70
SFP-Port 1000Base-LX mini-GBIC module - 70km (-40~75 degrees C)
Fast Ethernet SFP Transceiver Modules
MFB-FX
SFP-Port 100Base-F X Tra nsceiver (1310nm)-2km
MFB-F20
SFP-Port 100Base-F X Tra nsceiver (1310nm)-20km
MFB-F40
SFP-Port 100Base-F X Tra nsceiver (1310nm)-40km
MFB-F60
SFP-Port 100Base-F X Tra nsceiver (1310nm)-60km
MFB-FA20
SFP-Port 100Base-B X Tra nsceiver (W DM, TX:1310n m)-20km
MFB-FB20
SFP-Port 100Base-B X Tra nsceiver (W DM, TX:1550n m)-20km
MFB-TFX
SFP-Port 100Base-FX Transceiver (1310nm) -2km (-40~75 degrees C)
MFB-TF20
SFP-Port 100Base-FX Transceiver (1310nm) - 20km (-40~75 degrees C)
1. It is recommended to use PLANET SFPs on the
Managed Switch
. If you insert an SFP
transceiver that is not supported, the
Managed Switch
will not recognize it.
2. Please choose the SFP transceiver which can be operated under -40~75 degrees C
temperature if the switch device is working in an 0~50 degrees C temperature environment.
1000Base-SX/LX:
Before connecting the other switches, workstation or media converter.
1.
Make sure both sides of the SFP transceiver are with the same media type, for example, 1000Base-SX to 1000Base-SX,
1000Bas-LX to 1000Base-LX.
2.
Check the fiber-optic cable type that matches the SFP transceiver model.
To connect to 1000Base-SX SFP transceiver, use the multi-mode fiber cable with one side being the male duplex LC
connector type.
To connect to 1000Base-LX SFP transceiver, use the single-mode fiber cable with one side being the male duplex LC
connector type.
Connecting the fiber cable
1.
Attach the duplex LC connector on the network cable into the SFP transceiver.
2.
Connect the other end of the cable to a device – switches with SFP installed, fiber NIC on a workstation or a media
converter.
3.
Check the LNK/ACT LED of the SFP slot on the front of the
Managed Switch
. Ensure that the SFP transceiver is
operating correctly.
Summary of Contents for MGSD-10080F
Page 1: ...User s Manual of MGSD 10080F 1 ...
Page 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Page 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Page 358: ...User s Manual of MGSD 10080F 358 ...
Page 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Page 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Page 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Page 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...