User’s Manual of MGSD-10080F
332
Buttons
: Click to add a new community entry.
: Click to save changes.
:
Click to undo any changes made locally and revert to previously saved values.
4.17.2 RMON Alarm Status
This page provides an overview of RMON Alarm entries. Each page shows up to 99 entries from the Alarm table, default being
20, selected through the "entries per page" input field. When first visited, the web page will show the first 20 entries from the
beginning of the Alarm table. The first displayed will be the one with the lowest ID found in the Alarm table; screen in
Figure
4-17-2
appears.
Figure 4-17-2:
Port Statistics Overview page screenshot
The page includes the following fields:
Object
Description
•
ID
Indicates the index of Alarm control entry.
•
Interval
Indicates the interval in seconds for sampling and comparing the rising and
falling threshold.
•
Variable
Indicates the particular variable to be sampled
•
Sample Type
The method of sampling the selected variable and calculating the value to be
compared against the thresholds.
•
Value
The value of the statistic during the last sampling period.
•
Startup Alarm
The alarm that may be sent when this entry is first set to valid.
•
Rising Threshold
Rising threshold value.
•
Rising Index
Rising event index.
•
Falling Threshold
Falling threshold value.
•
Falling Index
Falling event index.
Summary of Contents for MGSD-10080F
Page 1: ...User s Manual of MGSD 10080F 1 ...
Page 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Page 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Page 358: ...User s Manual of MGSD 10080F 358 ...
Page 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Page 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Page 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Page 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...