User’s Manual of MGSD-10080F
145
4.6.10.3 Port Isolate
The diagram shows how the Managed Switch handles isolate and promiscuous ports, and the each PC is not able to access
each other PCs of each isolate port. But they all need to access with the same server/AP/Printer. The screen in
Figure 4-6-14
appears. This section will show you how to configure the port for the server – that could be accessed by each isolate port.
Figure 4-6-14:
The Port Isolate VLAN Diagram
Setup steps
1. Assign Port Mode
Set Port-1~Port-4 in Isolate port.
Set Port5 and Port-6 are in Promiscuous port. The screen in
Figure 4-6-15
appears.
Figure 4-6-15:
The Configuration of Isolate and Promiscuous Port
2. Assign VLAN Member :
VLAN 1 : Port-1,Port-2 ,Port-5 and Port-3
VLAN 2 : Port-3~Port-6. The screen in
Figure 4-6-16
appears.