![Planet MGSD-10080F User Manual Download Page 143](http://html1.mh-extra.com/html/planet/mgsd-10080f/mgsd-10080f_user-manual_1563316143.webp)
User’s Manual of MGSD-10080F
143
4.6.10.2 VLAN Trunking between two 802.1Q aware Switches
The most cases are used for “
Uplink
” to other switches. VLANs are separated at different switches, but they need to access
with other switches within the same VLAN group. The screen in
Figure 4-6-11
appears.
Setup steps
1. Create VLAN Group
Set VLAN Group 1 = Default-VLAN with VID (VLAN ID) =1
Add two VLANs – VLAN 2 and VLAN 3
VLAN Group 2 with VID=
2
VLAN Group 3 with VID=
3
2. Assign VLAN Member :
VLAN 2 : Port-1,Port-2 and Port-3
VLAN 3 : Port-4, Port-5 and Port-6
VLAN 1 : All other ports – Port-7~Port-24
About the VLAN ports connect to the hosts, please refer to 4.6.10.1 examples. The following steps will focus on the VLAN
Trunk
port
configuration.