![Planet MGSD-10080F User Manual Download Page 252](http://html1.mh-extra.com/html/planet/mgsd-10080f/mgsd-10080f_user-manual_1563316252.webp)
User’s Manual of MGSD-10080F
252
attributes must all be present at least once in the Access-Accept packet.
- The switch looks for the first set of these attributes that have the same
Tag value and fulfil the following requirements (if Tag == 0 is used, the
Tunnel-Private-Group-ID does not need to include a Tag):
- Value of Tunnel-Medium-Type must be set to "IEEE-802" (ordinal 6).
- Value of Tunnel-Type must be set to "VLAN" (ordinal 13).
- Value of Tunnel-Private-Group-ID must be a string of ASCII chars in the
range '0' - '9', which is interpreted as a decimal string representing the
VLAN ID. Leading '0's are discarded. The final value must be in the
range [1; 4095].
•
Guest VLAN Enabled
When Guest VLAN is both globally enabled and enabled (checked) for a given
port, the switch considers moving the port into the Guest VLAN according to the
rules outlined below.
This option is only available for EAPOL-based modes, i.e.:
• Port-based 802.1X
• Single 802.1X
• Multi 802.1X
For trouble-shooting VLAN assignments, use the "M
onitor→VLANs→VLAN
Membership and VLAN Port" pages. These pages show which modules have
(temporarily) overridden the current Port VLAN configuration.
Guest VLAN Operation:
When a Guest VLAN enabled port's link comes up, the switch starts transmitting
EAPOL Request Identity frames. If the number of transmissions of such frames
exceeds Max. Reauth. Count and no EAPOL frames have been received in the
meanwhile; the switch considers entering the Guest VLAN. The interval between
transmission of EAPOL Request Identity frames is configured with EAPOL
Timeout. If Allow Guest VLAN if EAPOL Seen is enabled, the port will now be
placed in the Guest VLAN. If disabled, the switch will first check its history to see
if an EAPOL frame has previously been received on the port (this history is
cleared if the port link goes down or the port's Admin State is changed), and if
not, the port will be placed in the Guest VLAN. Otherwise it will not move to the
Guest VLAN, but continue transmitting EAPOL Request Identity frames at the
rate given by EAPOL Timeout.
Once in the Guest VLAN, the port is considered authenticated, and all attached
clients on the port are allowed access on this VLAN. The switch will not transmit
an EAPOL Success frame when entering the Guest VLAN.
Summary of Contents for MGSD-10080F
Page 1: ...User s Manual of MGSD 10080F 1 ...
Page 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Page 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Page 358: ...User s Manual of MGSD 10080F 358 ...
Page 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Page 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Page 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Page 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...