![Planet MGSD-10080F User Manual Download Page 224](http://html1.mh-extra.com/html/planet/mgsd-10080f/mgsd-10080f_user-manual_1563316224.webp)
User’s Manual of MGSD-10080F
224
4.10.2 Access Control List Configuration
This page shows the Access Control List (ACL), which is made up of the ACEs defined on this switch. Each row describes the
ACE that is defined. The maximum number of ACEs is
256
on each switch.
Click on the lowest plus sign to add a new ACE to the list. The reserved ACEs used for internal protocol, cannot be edited or
deleted, the order sequence cannot be changed and the priority is highest.
The Access Control List Configuration screen in
Figure 4-10-2
appears.
Figure 4-10-2:
Access Control List Configuration Page Screenshot
The page includes the following fields:
Object
Description
•
Ingress Port
Indicates the ingress port of the ACE. Possible values are:
All:
The ACE will match all ingress port.
Port:
The ACE will match a specific ingress port.
•
Policy / Bitmask
Indicates the policy number and bitmask of the ACE.
•
Frame Type
Indicates the frame type of the ACE. Possible values are:
Any
: The ACE will match any frame type.
EType
: The ACE will match Ethernet Type frames. Note that an
Ethernet Type based ACE will not get matched by IP and ARP frames.
: The ACE will match ARP/RARP frames.
IPv4
: The ACE will match all IPv4 frames.
IPv4/ICMP
: The ACE will match IPv4 frames with ICMP protocol.
IPv4/UDP
: The ACE will match IPv4 frames with UDP protocol.
IPv4/TCP
: The ACE will match IPv4 frames with TCP protocol.
IPv4/Other
: The ACE will match IPv4 frames, which are not
ICMP/UDP/TCP.
IPv6
: The ACE will match all IPv6 standard frames.
•
Action
Indicates the forwarding action of the ACE.
Permit
: Frames matching the ACE may be forwarded and learned.
Deny
: Frames matching the ACE are dropped.
•
Rate Limiter
Indicates the rate limiter number of the ACE. The allowed range is 1 to 16. When
Disabled is displayed, the rate limiter operation is disabled.
•
Port Redirect
Indicates the ingress port of the ACE. Possible values are:
All:
The ACE will match all ingress port.
Summary of Contents for MGSD-10080F
Page 1: ...User s Manual of MGSD 10080F 1 ...
Page 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Page 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Page 358: ...User s Manual of MGSD 10080F 358 ...
Page 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Page 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Page 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Page 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...