User’s Manual of MGSD-10080F
508
6.14 LED Power Command
LED Power Timers
Description:
Set or show the time and intensity for the LEDs.
Syntax:
led_power timers [<hour>] [<intensity>]
Parameters:
<hour>
: The hour (0-23) at which to change LEDs intensity
<intensity>
: The LED intensity in % (0-100)
LED Power Delete Timer
Description:
Deletes a timer.
Syntax:
led_power delete_timer <hour>
Parameters:
<hour>
: The hour (0-23) at which to change LEDs intensity
LED Power Maintenance
Description:
Set or show the maintenance settings.
Syntax:
led_power maintenance [<maintenance_time>] [on_at_errors|leave_at_errors]
Parameters:
<maintenance_time>
: Time in seconds (0-65535) that the LEDs shall be turned on, when any port changes
link state on_at_errors|leave_at_errors: on_at_error if LEDs shall be turned on if any errors has been detected.
leave_at_errors if no LED change shall happen when errors have been detected