User’s Manual of MGSD-10080F
391
IEEE 802.1Q
Example:
Set VLAN mode in port base
MGSD-10080F:/>
vlan mode portbased
VLAN Link Type
Description:
Set or show the port VLAN link type.
Syntax:
VLAN LinkType [<port_list>] [untagged|tagged]
Parameters:
<port_list>
: Port list or 'all', default: All ports
untagged
: VLAN Link Type Tagged
tagged
: VLAN Link Type Untagged
(default: Show VLAN link type)
Default Setting:
Un-tagged
Example:
Enable tagged frame for port2
MGSD-10080F:/>
vlan linktype 2 tagged
VLAN Q-in-Q Mode
Description:
Set or show the port Q-in-Q mode.
Syntax:
VLAN QinQ [<port_list>] [disable|man|customer]