User’s Manual of MGSD-10080F
260
Selected Counters
Object
Description
•
Selected Counters
The Selected Counters table is visible when the port is one of the following
Multi 802.1X
MAC-based Auth
.
The table is identical to and is placed next to the Port Counters table, and will be empty if
no MAC address is currently selected. To populate the table, select one of the attached
MAC Addresses from the table below.
Attached MAC Address
Object
Description
•
Identity
Shows the identity of the supplicant, as received in the Response Identity EAPOL frame.
Clicking the link causes the supplicant's EAPOL and Backend Server counters to be
shown in the Selected Counters table. If no supplicants are attached, it shows No
supplicants attached.
This column is not available for MAC-based Auth.
•
MAC Address
For Multi 802.1X, this column holds the MAC address of the attached supplicant.
For MAC-based Auth., this column holds the MAC address of the attached client.
Clicking the link causes the client's Backend Server counters to be shown in the
Selected Counters table. If no clients are attached, it shows No clients attached.
•
VLAN ID
This column holds the VLAN ID that the corresponding client is currently secured
through the Port Security module.
•
State
The client can either be authenticated or unauthenticated. In the authenticated state, it is
allowed to forward frames on the port, and in the unauthenticated state, it is blocked. As
long as the backend server hasn't successfully authenticated the client, it is
unauthenticated. If an authentication fails for one or the other reason, the client will
remain in the unauthenticated state for Hold Time seconds.
•
Last Authentication
Shows the date and time of the last authentication of the client (successful as well as
unsuccessful).
Buttons
Auto-refresh
: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds.
: Click to refresh the page immediate.
Summary of Contents for MGSD-10080F
Page 1: ...User s Manual of MGSD 10080F 1 ...
Page 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Page 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Page 358: ...User s Manual of MGSD 10080F 358 ...
Page 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Page 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Page 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Page 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...