User’s Manual of MGSD-10080F
25
1.2 Product Descriptions
Multiple SFP Fiber Port Switch for Growing Long-Reach Networking of Enterprise, Telecoms and Campus
The MGSD-10080F is equipped with advanced management functions and provides
8 100/1000Mbps dual speed
SFP Fiber
ports, and
2 10/100/1000Mbps TP
ports delivered in a rugged strong case. It is capable of providing non-blocking switch fabric
and wire-speed throughput as high as
20Gbps
in the temperature range from
-10 to 60 degrees C
without any packet loss and
CRC error, which greatly simplify the tasks of upgrading the enterprise LAN for catering to increasing bandwidth demands. The
MGSD-10080F is specially designed for service provider to deliver profitable Ethernet network. The MGSD-10080F adopts
“
Front Access
” design, making the wiring and maintenance of the MGSD-10080F placed in a cabinet very easy for technicians.
AC and DC Redundant Power to ensure continuous operation
PLANET MGSD-10080F is equipped with one
100~240V AC
power supply unit and one additional
36 ~ 72V
DC
power supply
unit for redundant power supply installation. A redundant power system is also provided to enhance the reliability with either the
100~240V AC power supply unit or the DC 36 ~ 72V power supply unit. Redundant Power Systems are specifically designed to
handle the demands of high tech facilities requiring the highest power integrity. Furthermore, with the 36~ 72V DC power supply
implemented, the MGSD-10080F can be applied as the telecom level device that could be located in the electronic room.
Digital Input and Digital Output for external Alarm
PLANET MGSD-10080F supports Digital Input, and Digital Output on the front panel. This external alarm offers technicians the
ability to use Digital Input to detect, and log external device status (such as door intrusion detector ) for the alarm. As Digital
Output could be used to alarm if MGSD-10080F has port link down, link up or power failure.
Summary of Contents for MGSD-10080F
Page 1: ...User s Manual of MGSD 10080F 1 ...
Page 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Page 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Page 358: ...User s Manual of MGSD 10080F 358 ...
Page 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Page 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Page 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Page 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...