User’s Manual of MGSD-10080F
108
•
Configured Link Speed
Select any available link speed for the given switch port. Draw the menu bar to
select the mode.
All
- Setup whole ports with the same setting.
Auto Copper
- Setup Auto negotiation.
Auto Fiber
- Setup Auto negotiation.
10 Half
- Force sets 10Mbps/Half-Duplex mode.
10 Full
- Force sets 10Mbps/Full-Duplex mode.
100 Half
- Force sets 100Mbps/Half-Duplex mode.
100 Full
- Force sets 100Mbps/Full-Duplex mode.
1000 Full
- Force sets 10000Mbps/Full-Duplex mode.
Disable
- Shutdown the port manually.
•
Flow Control
When
Auto Speed
is selected on a port, this section indicates the flow control
capability that is advertised to the link partner.
When a fixed-speed setting is selected, that is what is used. The Current Rx
column indicates whether pause frames on the port are obeyed, and the Current
Tx column indicates whether pause frames on the port are transmitted. The Rx
and Tx settings are determined by the result of the last Auto-Negotiation.
Check the configured column to use flow control. This setting is related to the
setting for Configured Link Speed.
•
Maximum Frame Size
Enter the maximum frame size allowed for the switch port, including FCS. The
allowed range is 1518 bytes to 9600 bytes for TP port and 9000 bytes for Fiber
port.
•
Excessive Collision
Mode
Configure port transmit collision behavior.
Discard
: Discard frame after 16 collisions (default).
Restart
: Restart back off algorithm after 16 collisions.
•
Power Control
The Usage column shows the current percentage of the power consumption per
port. The Configured column allows for changing the power savings mode
parameters per port.
Disabled
: All power savings mechanisms disabled.
ActiPHY
: Link down power savings enabled.
PerfectReach
: Link up power savings enabled.
Enabled
: Both link up and link down power savings enabled.
When setting each port to run at 100M Full, 100M Half, 10M Full, and 10M Half-speed modes, the
Auto-MDIX function will disable.
Summary of Contents for MGSD-10080F
Page 1: ...User s Manual of MGSD 10080F 1 ...
Page 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Page 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Page 358: ...User s Manual of MGSD 10080F 358 ...
Page 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Page 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Page 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Page 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...