User’s Manual of GS-5220 LCD Series
197
•
Port VLAN
Determines the
port's VLAN ID
(
PVID
). Allowed VLANs are in the range
1 through 4095, default being 1.
■
On ingress, frames get classified to the Port VLAN if the port is
configured as VLAN unaware, the frame is untagged, or VLAN
awareness is enabled on the port, but the frame is priority tagged
(VLAN ID = 0).
■
On egress, frames classified to the Port VLAN do not get tagged if
Egress Tagging configuration is set to untag Port VLAN.
The Port VLAN is called an "
Access VLAN
" for ports in Access mode and
Native VLAN for ports in Trunk or Hybrid mode.