203
REV
AL 182
Use, maintenance and warning instructions
MEDIUM PRESSURE REGULATOR
|
MAINTENANCE AND FUNCTIONAL CHECKS
|
REV. 00
EN
Step Action
72
Insert and fix the screws (64) according to the following tightening torque:
• DN 6”: tab. 9.96
• DN 8”: tab. 9.97
NOTICE!
Tighten the screws according to the cross diagram in paragraph 9.4.2.2.
73
Position the control head inside the regulator housing (1) with the indicator slide (16) visible and parallel to the
gas flow.
NOTICE!
Take care not to damage the plug profile (2).
74
Insert and fix the screws (31) according to the following tightening torque:
• DN 6”: tab. 9.96
• DN 8”: tab. 9.97
NOTICE!
Tighten the screws according to the cross diagram in paragraph 9.4.2.2.
75
Insert the pawl (163) into the indicator rod (18).
NOTICE!
Check that the pawl (163) is in position 0% in relation to the indicator slide (16).
76
Insert the indicator slide (16) into the eyebolt flange (14).
77
Insert and fasten the screws (57).
78
Connect the pneumatic connections between the regulator and the respective control unit, including down-
stream pressure ports.
Tab. 9.148.
WARNING!
Ensure that all parts have been fitted correctly.