177
REV
AL 182
Use, maintenance and warning instructions
MEDIUM PRESSURE REGULATOR
|
MAINTENANCE AND FUNCTIONAL CHECKS
|
REV. 00
EN
Step Action
1
Unscrew and remove the screws (141).
2
Remove the cap (140).
3
Remove and replace O-ring (142) by lubricating it with synthetic grease.
NOTICE!
Before inserting the replacement O-ring, clean the retaining slots with a cleaning solution.
4
Insert cap (140).
5
Insert and fix the screws (141) according to the following tightening torque:
• DN 1”: tab. 9.91
• DN 2”: tab. 9.92
NOTICE!
Tighten the screws according to the cross diagram in paragraph 9.4.2.2.
Tab. 9.145.
WARNING!
Ensure that all parts have been fitted correctly.