120
REV
AL 182
EN
Use, maintenance and warning instructions
MEDIUM PRESSURE REGULATOR
|
COMMISSIONING
|
REV. 00
8.13.4 - PRESSURE SWITCH CALIBRATION MOD. SA
Fig. 8.45.
Calibration of pressure switches mod. SA
Adjust the maximum pressure (11) ring nut (13):
• anti-clockwise to decrease the slim-shut device tripping pressure;
• clockwise to increase the slim-shut device tripping pressure.
Turn the minimum pressure (17) ring nut (15):
• anti-clockwise to decrease the slim-shut device tripping pressure;
• clockwise to increase the slim-shut device tripping pressure.
NOTICE!
For calibration ranges, please refer to chapter 13 “Calibration tables”.
ATTENTION!
After calibration of the pressure switch, remove the lever to avoid interference with other objects on the
system.