185
REV
AL 182
Use, maintenance and warning instructions
MEDIUM PRESSURE REGULATOR
|
MAINTENANCE AND FUNCTIONAL CHECKS
|
REV. 00
EN
Step Action
48
Position the spacer (19).
49
Place the lower cover (3) on the plug guide (2).
NOTICE!
Match the hole for the passage of the loading pressure to the similar one on the plug guide.
50
Insert and fasten the screws of the lower part (27) in the lower cover (3) according to the tightening torque:
• DN 2” 1/2: tab. 9.93
• DN 3”: tab. 9.94
• DN 4”: tab. 9.95
NOTICE!
Tighten the screws according to the cross diagram in paragraph 9.4.2.2.
51
Put the diaphragm unit in place (10, 12, 13, 21, 29, 45, 50, 62).
52
Insert and secure the balancing stem guide (11) according to the tightening torque:
• DN 2” 1/2: tab. 9.93
• DN 3”: tab. 9.94
• DN 4”: tab. 9.95
NOTICE!
Hold the diaphragm assembly in place by positioning the spanner in the holes in the upper dia
-
phragm support (13).
53
Position the upper cover (3), taking care to position the indicator stem (18) in the space between the upper
diaphragm support (13) and the balance stem guide (11).
NOTICE!
•
The indicator rod (18) must not obstruct the transfer hole (21) on the upper diaphragm sup
-
port (13)
•
The flange travel indicator must be visible and perpendicular to the gas flow
54
Insert and fasten the screws (25) with the nuts (26) according to the tightening torque:
• DN 2” 1/2: tab. 9.93
• DN 3”: tab. 9.94
• DN 4”: tab. 9.95
NOTICE!
Tighten the screws according to the cross diagram in paragraph 9.4.2.2.
55
Position the spring holder (34) and spring (54).
NOTICE!
Check that the spring (54) is properly seated in the centring stop on the plug guide (2).
56
Insert locking nut (9)
57
Insert the plug (5).
58
Insert the washer (23).
Summary of Contents for REVAL 182
Page 404: ......