7 Software
7.7.4
PLC Settings for A/B Trigger from single-ended inputs
This configuration maps the single-ended inputs to the A/B camera inputs: ISO_IN0 is mapped
to the A signal and ISO_IN1 to the B signal see Table 7.3 (the visibility in the PF_GEVPlayer must
be set to
Guru
for this purpose).
The AB Trigger feature is not available on all camera revisions, see Appendix B
for a list of available features.
Feature
Value
Category
TriggerMode
On
AcquisitionControl
TriggerSource
ABTrigger
AcquisitionControl
PLC_I0
Line0
<PLC>/SignalRoutingBlock
PLC_I1
Line1
<PLC>/SignalRoutingBlock
PLC_Q6_Variable0
PLC_I0
<PLC>/LookupTable/Q6
PLC_Q6_Operator0
Or
<PLC>/LookupTable/Q6
PLC_Q6_Variable1
Zero
<PLC>/LookupTable/Q6
PLC_Q6_Operator1
Or
<PLC>/LookupTable/Q6
PLC_Q6_Variable2
Zero
<PLC>/LookupTable/Q6
PLC_Q6_Operator2
Or
<PLC>/LookupTable/Q6
PLC_Q6_Variable3
Zero
<PLC>/LookupTable/Q6
PLC_Q7_Variable0
PLC_I1
<PLC>/LookupTable/Q7
PLC_Q7_Operator0
Or
<PLC>/LookupTable/Q7
PLC_Q7_Variable1
Zero
<PLC>/LookupTable/Q7
PLC_Q7_Operator1
Or
<PLC>/LookupTable/Q7
PLC_Q7_Variable2
Zero
<PLC>/LookupTable/Q7
PLC_Q7_Operator2
Or
<PLC>/LookupTable/Q7
PLC_Q7_Variable3
Zero
<PLC>/LookupTable/Q7
Table
7.3:
PLC
Settings
for
A/B
Trigger
from
single-ended
inputs
(<PLC>
=
in
category
IPEngine/ProgrammableLogicController)
.
82
Summary of Contents for MV1-R1280-50-G2 Camera Series
Page 6: ...CONTENTS 6...
Page 10: ...2 Introduction 10...
Page 14: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 14...
Page 30: ...4 Product Specification 30...
Page 51: ...Figure 5 19 Crosshairs Example with different grey values 5 6 Crosshairs 51...
Page 72: ...6 Hardware Interface 72...
Page 84: ...7 Software 84...
Page 88: ...9 Warranty 88...
Page 90: ...10 References 90...
Page 94: ...B Camera Revisions 94...
Page 95: ...C Document Revision History Revision Date Changes 1 0 April 2015 First version 95...