![Photon Focus MV1-R1280-50-G2 Camera Series User Manual Download Page 65](http://html1.mh-extra.com/html/photon-focus/mv1-r1280-50-g2-camera-series/mv1-r1280-50-g2-camera-series_user-manual_1553554065.webp)
Fig. 6.9 shows the connection from ISO_OUT1 to a LED.
Y
O U R _ P W
R
I S O _ G N D
P o w e r
M O S F E T
I S O _ O U T 1
P T C
R
C a m
e r a
8
1 2 p o l . H i r o s e
C o n n e c t o r
I S O _ G N D
1 2
Y O U R _ G N D
+
Figure 6.9: Connection from ISO_OUT1 to a LED
Respect the limits of the POWER MOSFET in the connection to ISEO_OUT1. Max-
imal ratings that must not be exceeded: voltage: 30 V, current: 0.5 A, power: 0.5
W. (see also Fig. 6.10). The type of the Power MOSFET is: International Rectifier
IRLML0100TRPbF.
Y
O U R _ P W
R
I S O _ G N D
P o w e r
M O S F E T
I S O _ O U T 1
P T C
L
C a m
e r a
8
1 2 p o l . H i r o s e
C o n n e c t o r
I S O _ G N D
1 2
Y O U R _ G N D
Y O U R _ P W
R
L
D
D
D
1
2
M a x . 3 0 V
M a x . 0 . 5 A
M a x . 0 . 5 W
+
+
R e s p e c t t h e l i m
i t s o f t h e P O W
E R M O S F E T !
Figure 6.10: Limits of ISO_OUT1 output
.
6.5 Trigger and Strobe Signals for GigE Cameras
65
Summary of Contents for MV1-R1280-50-G2 Camera Series
Page 6: ...CONTENTS 6...
Page 10: ...2 Introduction 10...
Page 14: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 14...
Page 30: ...4 Product Specification 30...
Page 51: ...Figure 5 19 Crosshairs Example with different grey values 5 6 Crosshairs 51...
Page 72: ...6 Hardware Interface 72...
Page 84: ...7 Software 84...
Page 88: ...9 Warranty 88...
Page 90: ...10 References 90...
Page 94: ...B Camera Revisions 94...
Page 95: ...C Document Revision History Revision Date Changes 1 0 April 2015 First version 95...