5 Functionality
TriggerMode
= Off. In Constant Frame Rate mode (
AcquisitionFrameRateEnable
= True),
exposure starts after a user-specified time has elapsed from the previous exposure start so
that the resulting frame rate is equal to the value of
AcquisitionFrameRate
.
Software Trigger
The trigger signal is applied through a software command (
TriggerSoftware
in category
AcquisitionControl
). Settings for Software Trigger mode:
TriggerMode
= On
and
TriggerSource
= Software.
Line1 Trigger
The trigger signal is applied directly to the camera by the power supply
connector through pin ISO_IN1 (see also Section A.1). A setup of this mode is shown in
Fig. 5.3 and Fig. 5.4. The electrical interface of the trigger input and the strobe output is
described in Section 6.5. Settings for Line1 Trigger mode:
TriggerMode
= On and
TriggerSource
= Line1.
PLC_Q4 Trigger
The trigger signal is applied by the Q4 output of the PLC (see also Section 6.6).
Settings for PLC_Q4 Trigger mode:
TriggerMode
= On and
TriggerSource
= PLC_Q4.
ABTrigger
Trigger from incremental encoder (see Section 5.2.9). The A/B Trigger feature is not
available on all camera revisions, see Appendix B for a list of available features.
Some trigger signals are inverted. A schematic drawing is shown in Fig. 7.4.
Figure 5.3: Trigger source
34
Summary of Contents for MV1-R1280-50-G2 Camera Series
Page 6: ...CONTENTS 6...
Page 10: ...2 Introduction 10...
Page 14: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 14...
Page 30: ...4 Product Specification 30...
Page 51: ...Figure 5 19 Crosshairs Example with different grey values 5 6 Crosshairs 51...
Page 72: ...6 Hardware Interface 72...
Page 84: ...7 Software 84...
Page 88: ...9 Warranty 88...
Page 90: ...10 References 90...
Page 94: ...B Camera Revisions 94...
Page 95: ...C Document Revision History Revision Date Changes 1 0 April 2015 First version 95...