S
ERVICE
P
ROCEDURES
: N
EUTRIK
T
RUE
O
NE
AC I
NPUT
C
ONNECTOR
02.9704.0010 A
Note: All procedures are done with the power completely removed. Adhere to all warnings in this manual.
39
2
Neutrik True One AC Input Connector
Vari-Lite Part No: 25.9704.0830
To replace Neutrik True One AC input connector:
Step 1. Remove connector side enclosure cover following the procedure described in
Enclosure Covers Removal” on page 25
Step 2. Disconnect wiring from Neutrik True One connector.
Step 3. At front, remove 2 x 4-40 x 3/8" PFB screws.
Step 4. Inside enclosure, remove backing plate and set aside. It will be reinstalled with replacement
connector.
Step 5. Remove Neutrik True One connector.
Step 6. Replace in reverse.
Note:
Drawing exploded and some
components removed for clarity.
Screws
Neutrik True
Backing
Plate
One Connector