Fault finding and repair tips
GB 23
EM1A
5.
Figure 5-8
CL 06532130_021.eps
171000
on
+5V and +8V levels can be detected by the Painter. Vcc of the HOP is present.
Activate protection for +8V and +5V
Deflection starts on 50kHz; +5V and +8V become present
5V2 present on the HOP. HOP starts in low power start up mode
Mute
Initialize I/O pins of the OTC
Make 'Standby-info' low
Standby bit set in NVM?
Degaussing is activated automatically and should
be acivated after 12 seconds
Standby-supply is running; +3.3V, +5V2 ready
'Standby-info' = high;
µ
P has been reset by POR
Standby supply starts oscillating
off
Low_power_standby
High_power_standby
no
no
yes
yes
POR available within 1 second ?
Standby high
Go to protection
Error code 05
'HOP POR
not successfull'
read POR bit from the HOP
Wait 1500ms and reset MSP
(Sound-IC)
DISABLE I2C while EHT is starting up: 250ms
Give HOP_start_commando within 23.5 ms after a
POR is obtained from the HOP
HOP_on
Main_power_on
Supply is in standby-mode
'Standby-info' remains
high
From here onwards,
I2C communication is
possible
Set Black Current Stabilisation = Active
Initialize I2C IC's
Put 'Standby-INFO' high again
Activate I2C protection. Set protection algorithms active for
I2C, +5V, +8V, HFB, FBX