EN 68
3139 785 31532
Firmware Upgrading & Diagnostic Software
5.
Nucleus Name
DS_SYS_SettingsDoubleCheck
Nucleus Number
1233
Description
Double check whether stored HW-string equals actual HW as far
as we can automatically detect this. An automatic and a manual mode is
supported.
Technical
-
Read out the HW diversity string
-
Check whether these settings correspond the actual hardware
-
In case of modification: Write back the new HW-diversity settings.
Execution Time
4 seconds in auto mode when everything matches
User Input
-
‘manual’ or ‘MANUAL’ to enter manual mode
-
default is automatic mode where the nucleus stops upon and reports the
first encountered error
Error Number
Description
123300
Double checking the HW-diversity settings succeeded
123301
Double check failed, a difference in settings was encountered
123302
Reading the HW-diversity settings failed
123303
Writing the modified HW-diversity settings failed
Example
DS:> 1233
123300:
Test OK @
DS:> 1233 manual
123300:
Test OK @
DS:> 1233
123301:
Hardware ID mismatch: in HW-Diversity string:99, actual in FLASH:0
Error @
DS:> 1233 manual
Hardware ID mismatch! in HW-Diversity string:99, actual in FLASH:0
Enter the correct HW ID of the digital board.
> 0
The HW-diversity string has been modified by you. Settings:
Board name: DIAG
Hardware ID: 0
Codec IC: PNX7100_MF3
Video Input Processor IC: SAA7118
Progressive Scan Deinterlacer IC: None
Progressive Scan Denc IC: ADV7196
I-Link physical layer circuit IC: PDI1394P25
I-Link link layer circuit IC: PDI1394P40
Audio clock: Clock scheme 1
Bit engine connector: available
IDE connector 1: available
IDE connector 2: not available
PCI connector: not available
RAM size 32MByte
ROM size (NOR FLASH bank 1) 8MByte
ROM size (NOR FLASH bank 2) Not available
ROM size (NAND FLASH) Not available
Is it OK to program this in
the new HW-diversity string? ([y]es/[n]o):y
Diversity HW-string programmed successfully.
123300:
Test OK @
DS:>